As reported, at the end of a transjugular intrahepatic portosystemic shunt (tips) procedure, a flexor guiding sheath unraveled upon removal of the device.The anatomy was not tortuous, calcified, or scarred.Resistance was encountered upon removal of the device from the patient, and the sheath's inner coil unraveled.The device, which did not fully separate, was removed from the patient intact.A section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.
|
|
Blank fields on this form indicate the information is unknown, unchanged, or unavailable.Summary of event: as reported, at the end of a transjugular intrahepatic portosystemic shunt (tips) procedure, a flexor guiding sheath unraveled upon removal of the device.The anatomy was not tortuous, calcified, or scarred.Resistance was encountered upon removal of the device from the patient, and the sheath's inner coil unraveled.The device, which did not fully separate, was removed from the patient intact.A section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.Investigation evaluation: reviews of the complaint history, device history record, instructions for use (ifu), manufacturing instructions, and quality control procedures were conducted during the investigation.A visual inspection of the complaint device was also conducted.The used complaint device was returned to cook for investigation.The inner coil was found protruding from the silicone disc of the hub.A document-based investigation evaluation was performed.No related non-conformances were found, and there have been no other reported complaints for this lot number.The product ifu warns, ¿reinsertion of dilator prior to removal of flexor sheath increases the strength of the sheath and lessen the risk of device separation.If resistance is anticipated or encountered during withdrawal of flexor sheath, consider carefully reinserting the dilator to continual removal.¿ the information provided upon review of the dmr, dhr, ifu, and investigation of the returned device suggests that there is evidence the device was manufactured to specification.There is no evidence of non-conforming devices in-house or in the field.Cook has concluded that sufficient inspection activities are in place to identify this failure mode prior to distribution.Based on the information provided and the results of the investigation, cook has concluded that a component failure unrelated to manufacturing contributed to this incident.The risk analysis for this failure mode was reviewed and no additional escalation was required.The appropriate personnel have been notified and cook will continue to monitor for similar events.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
|