In the literature titled ¿risk factors of delayed bleeding after cold snare polypectomy for colorectal polyps: a multicenter study,¿ patients experienced delayed bleeding (db) after cold snare polypectomy (csp) procedures using olympus devices.Case with patient identifier (b)(6) reports pcf-q260azi.Case with patient identifier (b)(6) reports pcf-q260ai.Case with patient identifier (b)(6) reports pcf-h290i.Case with patient identifier (b)(6) reports pcf-h290zi.Case with patient identifier (b)(6) reports cf-hq290i.Case with patient identifier (b)(6) reports sd-210l-10.Case with patient identifier (b)(6) reports sd-400u-10.Study background/aim: delayed bleeding (db) rarely occurs after cold snare polypectomy (csp) for colorectal polyps, but no large-scale studies have investigated this.The study evaluated the rate, characteristics, and risk factors of db of csp.Methods: a multicenter retrospective study at 10 japanese institutions.A total of 18,007 patients underwent csp for colorectal polyps = 10 mm in size from march 2015 to september 2019, and cases of db (db group) were analyzed for the rate, antithrombotic drugs, polyp size, morphology, location, and risk factors.As a control, 269 non-bleeding cases (non-db group) with 606 polyps who underwent csp at the same 10 facilities in the 2-week study period were extracted.Results: 26 db cases were analyzed with 28 lesions, and the total db rate was 0.14% (26/18,007).The db group had significantly higher rates of using antiplatelets (42.3% vs.13.0%, p < 0.001) and anticoagulants (19.2% vs.2.6%, p = 0.002), and significantly higher rates of polyp size = 5 mm (67.9% vs.45.2%, p = 0.015), rectal lesion (25.0% vs.6.6%, p = 0.003), and polypoid lesion (89.3% vs.55.3%, p < 0.001) than the non-db group.A multivariate analysis (odds ratio; 95% confidence interval) for patient characteristics showed antiplatelet use (4.521; 1.817¿11.249, p = 0.001) and anticoagulant use (7.866; 20.63¿29.988, p = 0.003) as independent risk factors for db.Polyp size = 5 mm (3.251; 1.417¿7.463, p = 0.005), rectal lesion (3.674; 1.426¿9.465, p = 0.007), and polypoid lesion (7.087; 20.81¿24.132, p = 0.002) were also risk factors for lesion characteristics.Conclusion: the rate of db was 0.14% and antithrombotic drug use, polyp size, location, and morphology were related to it.In all db cases, endoscopic clipping was performed to achieve hemostasis.There were no cases who received blood transfusion.Db occurred 0¿5 days after csp, with an average of 1.6 ± 1.3 days later.Db most frequently occurred on the first day after csp (57.7%).There is no report of olympus device malfunction described in this study.
|