| Model Number |
96-2133 |
| Medical Device Problem Code |
Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Pain (1994); Synovitis (2094); Insufficient Information (4580)
|
| Date of Event |
02/16/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
Clinical notification received for revision of left knee to address polyethylene wear date of implantation: (b)(6) 2002.Date of revision: (b)(6) 2022.(left knee).Treatment: revision of tibial insert and patella components.Product details: catalog: 129434130.Lot: v49as1003.Description: mbt porocoat keel sz 3.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # : (b)(4).Investigation summary : an analysis of the product could not be performed since a physical sample was not received for evaluation.As part of our company quality system process, all devices are manufactured, inspected, and distributed to approved specifications.Additional complaint information monitoring for potential safety signals will be conducted through complaint trending as part of the post-market surveillance.However, if the product is received at a later date, the investigation will be updated as applicable.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.Device history lot : the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).A manufacturing records evaluation (mre) was not performed.
|
| |
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthes joint reconstruction, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
Medical records and operative notes reviewed indicating that "on (b)(6) 2022, patient's left knee was revised to address pain.The knee had been in place for ~twenty years.The surgeon found evidence of foreign body synovitis, as a consequence of polyethylene wear debris.The tibial insert was found to be very worn posterior medially and posterior laterally, with marked delamination.The patella component also was found to have delamination wear, primarily centrally worn.It was well-fixed though, as was the tibial tray and femur components.The patella was revised, as was the tibial insert--femur and tibial tray were retained.Multiple pulsatile lavages were performed on the soft tissues, to remove the polyethylene debris.No surgical complications were identified.".
|
| |
|
Search Alerts/Recalls
|