Model Number G30365
Medical Device Problem Codes Material Rupture (1546); Material Twisted/Bent (2981)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/17/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This report includes information known at this time.A follow up report will be submitted should additional relevant information become available.
 
Event or Problem Description
As reported, an ultraxx nephrostomy balloon and set ruptured at an unknown pressure.The device was used for access during a percutaneous nephrolithotomy.The balloon was "extremely difficult" to inflate and the knob was hard to turn.After the rupture, the sheath was placed over the balloon and bent in two places (it is unknown which device bent).A new device was used to complete the procedure successfully.No unintended section of the device remained inside the patient.The patient did not require any additional procedures due to the occurrence.The patient did not experience any adverse effects.
 
Additional Manufacturer Narrative
Event summary: as reported, an ultraxx nephrostomy balloon and set ruptured at an unknown pressure.The device was used for access during a percutaneous nephrolithotomy.The balloon was "extremely difficult" to inflate and the knob was hard to turn.After the rupture, the sheath was placed over the balloon and bent in two places (it is unknown which device bent).A new device was used to complete the procedure successfully.No unintended section of the device remained inside the patient.The patient did not require any additional procedures due to the occurrence.The patient did not experience any adverse effects.Investigation - evaluation.Reviews of the complaint history, device history record, instructions for use, specifications, and quality control procedures of the device were conducted during the investigation.No device was returned for investigation.A document-based investigation evaluation was performed.No related non-conformances were recorded.One additional complaint was reported for this lot number for an unrelated failure mode.The device history record review provides objective evidence that the device was manufactured to specification.There is no evidence of nonconforming devices from the complaint lot in house or in the field.A review of relevant manufacturing documents was conducted.There is no indication that a design or process related failure mode contributed to the reported event.Sufficient inspection activities are in place to identify this failure mode prior to distribution.The device is provided with instructions for use which state, ¿make all aspiration and injection maneuvers with the lock lever pushed left, i.E., unlocked.In this position, you can freely pull the piston back for aspiration, or push it forward for injection.To lock the piston in position, slide the lever right to the straight up position¿10.To inflate the balloon, engage the lock lever, turn the palm grip on the piston clockwise slowly until the desired inflation pressure is reached.Close the stopcock, (lock lever) on the inflation device to maintain pressure.¿ based on the available information, cook has concluded that a cause for this event could not be established.Cook will continue monitoring of similar complaints and has notified the appropriate personnel of this event.Per the quality engineering risk assessment, no further action is required.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Event or Problem Description
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRAXX NEPHROSTOMY BALLOON AND SET
Common Device Name
LJE CATHETER, NEPHROSTOMY
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
Manufacturer (Section G)
COOK INC.
750 daniels way
bloomington IN 47404
Manufacturer Contact
jason crouch
750 daniels way
bloomington, IN 47404
8123392235
MDR Report Key13971384
Report Number1820334-2022-00512
Device Sequence Number11915121
Product Code LJE
UDI-Device Identifier00827002303652
UDI-Public(01)00827002303652(17)241019(10)14289788
Combination Product (Y/N)N
Initial Reporter StateGA
Initial Reporter CountryUS
PMA/510(K) Number
K024050
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 05/23/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/19/2024
Device Model NumberG30365
Device Catalogue NumberUNBS-10-15
Device Lot Number14289788
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 03/17/2022
Supplement Date Received by Manufacturer05/12/2022
Initial Report FDA Received Date03/31/2022
Supplement Report FDA Received Date05/23/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured10/19/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-