Model Number 1012447-12
Medical Device Problem Code Device Markings/Labelling Problem (2911)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/09/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device is expected to be returned for investigation.It has not yet been received.A follow-up report will be submitted with all additional relevant information.
 
Event or Problem Description
It was reported that the packaging appeared intact; however, upon opening the 2.50 x 12mm nc trek rx balloon dilatation catheter (bdc), a 2.5 x 15mm nc trek bdc was in the hoop.The device was not used, there was no patient involvement and no clinically significant delay.No additional information was provided.
 
Additional Manufacturer Narrative
Visual inspection was performed on the returned device.The reported complaint was confirmed.Upon investigation, it was determined that the respective lots were manufactured approximately one month apart and in different production lines at the abbott vascular costa rica production site, which indicates the two units involved in this complaint never came into contact with one another during production.Additionally, a query of the system indicated that both lots were sold to the account.All currently available evidence points to the placement of the 2.50x15 mm nc trek bdc in the chipboard box for a 2.50x12 mm nc trek bdc having occurred at the hospital.In this case, it is possible that the 2.50x15 mm nc trek bdc was inadvertently placed in the wrong chipboard box after being pulled for a different procedure, but not used.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no other similar incidents and/or complaints from this lot.The investigation determined the reported complaint appears to be related to operational context.There is no indication of a product quality issue with respects to the design, manufacture, or labeling of the device.E1: title of initial reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NC TREK CORONARY DILATATION CATHETER
Common Device Name
CORONARY DILATATION CATHETER
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR COSTA RICA, REG # 3009564766
52 calle 3 b31 coyol free zone
el coyol alajuela
CS  
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key13973200
Report Number2024168-2022-03450
Device Sequence Number20035069
Product Code LOX
UDI-Device Identifier08717648151750
UDI-Public08717648151750
Combination Product (Y/N)N
Initial Reporter StateAZ
Initial Reporter CountryUS
PMA/510(K) Number
K103153
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 05/24/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/31/2024
Device Model Number1012447-12
Device Catalogue Number1012447-12
Device Lot Number11124G1
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 03/09/2022
Supplement Date Received by Manufacturer05/20/2022
Initial Report FDA Received Date04/01/2022
Supplement Report FDA Received Date05/24/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured11/24/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-