| Model Number |
N/A |
| Medical Device Problem Code |
Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
03/10/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported by healthcare professional "there was a nurse that identified a port that was leaking after it was placed on a patient on thursday (b)(6).No harm was done.The nurse believes there is a nick in the tubing.I did flush some saline through the tubing and did not see anything".
|
| |
|
Additional Manufacturer Narrative
|
|
The manufacturer has received the sample and is pending evaluation.Results are expected soon.A lot history review (lhr) of asfuf108 showed no other similar product complaint(s) from this lot number.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, trend analysis, applicable previous investigation(s), sample (if available), and applicable fmea documents.Based on a review of this information, the following was concluded: the complaint of a leaking infusion set was unconfirmed because the problem could not be reproduced.The product returned for evaluation was one 20ga x 1¿ powerloc max safety infusion set with y-site.Usage residues were observed throughout the sample and the safety mechanism was engaged.A needleless injection cap was attached to the proximal luer adapter and a curos cap was attached to the y-site luer.Microscopic inspection of the sample did not reveal any evidence of current or prior leakage.An attempt to infuse water through the sample using a 12ml syringe revealed the sample to be patent to infusion and aspiration with no observed leaks.No leaks were observed during sustained (>15 seconds) pressurization.No deficiencies were discovered during evaluation of the returned sample.Consequently this complaint is unconfirmed at this time.
|
| |
|
Event or Problem Description
|
|
It was reported by healthcare professional "there was a nurse that identified a port that was leaking after it was placed on a patient on thursday march 10th.No harm was done.The nurse believes there is a nick in the tubing.I did flush some saline through the tubing and did not see anything".
|
| |
|