• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ZIMMER BIOMET, INC. FEMUR CEMENTED STANDARD RIGHT SIZE 9; PROSTHESIS, KNEE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ZIMMER BIOMET, INC. FEMUR CEMENTED STANDARD RIGHT SIZE 9; PROSTHESIS, KNEE Back to Search Results
Model Number N/A
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Bone Fracture(s) (1870); Pain (1994); Osteopenia/ Osteoporosis (2651)
Date of Event 12/14/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Multiple mdr reports were filed for this event, please see associated reports: 0001822565-2022-00936, 0001822565-2022-00937, 0001822565-2022-00938, 0001822565-2022-00939, 0001822565-2022-00940, 0001822565-2022-00941, 0001822565-2022-00943, 0001822565-2022-00944, and 0001822565-2022-00946.Medical devices: femoral distal augment cemented size 9, 9+ 10 mm thickness, catalog#: 42556606610, lot#: 64475630.Femoral posterior augment cemented size 9, 9+ 5 mm thickness, catalog#: 42556806605, lot#: 64416182.Femoral posterior augment cemented size 9, 9+ 5 mm thickness, catalog#: 42556806605, lot#: 64459736.Femoral central cone size small, catalog#: 42545001011, lot#: 64500868.Tibia fixed cemented right size c, catalog#: 42542006402, lot#: ni.Tibial central cone size small, catalog#: 42545000511, lot#: 64627891.Tibial augment cemented half block right medial size cd 15 mm thickness, catalog#: 42555803415, lot#: 64664300.Tibial augment cemented half block right lateral size cd 15 mm thickness, catalog#: 42555803215, lot#: 64664291.Stem extension straight splined uncemented 12 mm diameter +175 mm length, catalog#: 42560117512, lot#: 64653842.Palacos cement, catalog#: 5036964, lot#: 94944865.Stem extension straight splined uncemented 14 mm diameter +135 mm length, catalog#: 42560113514 lot#: 64707053.Articular surface fixed bearing constrained condylar knee (cck) right 14 mm height, catalog#: 42522800514, lot#: 64372518.Customer has indicated that the product will not be returned to zimmer biomet for investigation, as it remains implanted.The investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event or Problem Description
It was reported that approximately one year post-implantation, the patient reports persistent pain.Radiology results reveal increased radiolucency concerning for loosening of the tibia and a stable periprosthetic fracture at the lateral femoral condyle.Due to the bone loss from two prior revisions, the patient does not want to pursue another revision and will be treated conservatively at this time.
 
Event or Problem Description
No further event information available at the time of this report.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional information.Suggested component code: mechanical (04) - femur.Reported event was confirmed by review of medical records.Medical records were provided and reviewed by a health care professional.Review of the available records identified the following: a lateral femoral condyle fracture occurred, x-rays showed radiolucency, and radiographic evidence of loosening, and bone loss.Device history record was reviewed and no discrepancies relevant to the reported event were found.Review of complaint history found no additional related issues for this item and the reported part and lot combination.Root cause was unable to be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FEMUR CEMENTED STANDARD RIGHT SIZE 9
Common Device Name
PROSTHESIS, KNEE
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
Manufacturer (Section G)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
Manufacturer Contact
christina arnt
56 e. bell dr.
warsaw, IN 46582
5745273773
MDR Report Key13977689
Report Number0001822565-2022-00942
Device Sequence Number14923017
Product Code JWH
UDI-Device Identifier00889024562585
UDI-Public(01)00889024562585(17)300908(10)64862199
Combination Product (Y/N)N
Initial Reporter StateWI
Initial Reporter CountryUS
PMA/510(K) Number
K191625
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Consumer,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 07/21/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue Number42504606602
Device Lot Number64862199
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/07/2022
Supplement Date Received by Manufacturer07/13/2022
Initial Report FDA Received Date04/01/2022
Supplement Report FDA Received Date07/21/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured09/14/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
N/A
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SEE H10.
Outcome Attributed to Adverse Event Other;
Patient SexMale
Patient Weight106 KG
-
-