• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: FX SOLUTIONS HUMERIS REVERSIBLE; REVERSIBLE SHOULDER PROSTHESIS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

FX SOLUTIONS HUMERIS REVERSIBLE; REVERSIBLE SHOULDER PROSTHESIS Back to Search Results
Model Number 313-0706
Health Effect - Clinical Code Joint Dislocation (2374)
Date of Event 03/17/2022
Type of Reportable Event Serious Injury
Event or Problem Description
The patient was revised on (b)(6) 2022 due to dislocation.Approximately 4 years and 9 months after the first surgery.The surgeon explanted 1 humeral cup (36/6).The surgeon implanted 1 humeral cup (36/6).
 
Additional Manufacturer Narrative
This mdr has already been submitted to fda by the us importer with report number (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HUMERIS REVERSIBLE
Common Device Name
REVERSIBLE SHOULDER PROSTHESIS
Manufacturer (Section D)
FX SOLUTIONS
1663 rue des majornas
viriat, 01440
FR  01440
Manufacturer (Section G)
FX SOLUTIONS
1663 rue des majornas
viriat, 01440
FR   01440
Manufacturer Contact
ratsamy thevenin
1663 rue des majornas
viriat, 01440
FR   01440
MDR Report Key13994453
Report Number3009532798-2022-00090
Device Sequence Number4372837
Product Code PHX
UDI-Device Identifier03701037301364
UDI-Public03701037301364
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K150488
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Device Explanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 03/24/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Expiration Date01/01/2022
Device Model Number313-0706
Device Catalogue Number313-0706
Device Lot NumberK1301
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 03/24/2022
Initial Report FDA Received Date04/04/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization;
Patient SexUnknown
-
-