BOSTON SCIENTIFIC CORPORATION EXPECT SLIMLINE (SL); ENDOSCOPIC ULTRASOUND SYSTEM, GASTROENTEROLOGY-UROLOGY Back to Search Results
Model Number M00555531
Medical Device Problem Codes Mechanical Problem (1384); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/09/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).The device has not been received for analysis.Upon receipt and completion of the problem analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.
 
Event or Problem Description
It was reported to boston scientific corporation that an expect slimline needle was used in the lungs during an endoscopic ultrasound (eus) procedure performed on (b)(6)2022.During the procedure, one lymph node was punctured successfully with the expect needle three times.However, after puncturing the second lymph node on the second attempt time the resistance in the handle was gone and the needle in the patient wasn't extending or retracting.The needle was still 2 cm out, but they carefully removed the needle together with the scope.The procedure was aborted.There were no patient complications reported as a result of this event.
 
Event or Problem Description
It was reported to boston scientific corporation that an expect slimline needle was used in the lungs during an endoscopic ultrasound (eus) procedure performed on (b)(6)2022.During the procedure, one lymph node was punctured successfully with the expect needle three times.However, after puncturing the second lymph node on the second attempt time the resistance in the handle was gone and the needle in the patient wasn't extending or retracting.The needle was still 2 cm out, but they carefully removed the needle together with the scope.The procedure was aborted.There were no patient complications reported as a result of this event.
 
Additional Manufacturer Narrative
Block h6: impact code f1001 is being used to capture the reportable issue of aborted/cancelled procedure.Block h10: investigation results: the returned acquire eus fnb needle was analyzed, and a functional evaluation noted that the needle could not be retracted correctly.The handle was disassemble and it was revealed that the needle was detached from the proximal luer.No other issues were noted.Based on all available information and the condition of the returned device, the device met all manufacturing requirements and no abnormalities were reported during the manufacturing process.The investigation concluded the most probable cause is cause not established.A review of the manufacturing documentation for this device revealed that no anomalies or deviations related to the event occurred during manufacturing.A labeling review was performed and, from the information available, this device was used per the directions for use (dfu) / product label.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EXPECT SLIMLINE (SL)
Common Device Name
ENDOSCOPIC ULTRASOUND SYSTEM, GASTROENTEROLOGY-UROLOGY
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
780 brookside drive
spencer IN 47460
Manufacturer Contact
carole morley
300 boston scientific way
marlborough, MA 01752
5086834015
MDR Report Key14003928
Report Number3005099803-2022-01519
Device Sequence Number20116599
Product Code ODG
UDI-Device Identifier08714729848806
UDI-Public08714729848806
Combination Product (Y/N)N
Initial Reporter CountryNL
PMA/510(K) Number
K163058
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 07/20/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/19/2025
Device Model NumberM00555531
Device Catalogue Number50266
Device Lot Number0028714767
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 03/10/2022
Supplement Date Received by Manufacturer06/24/2022
Initial Report FDA Received Date04/04/2022
Supplement Report FDA Received Date07/20/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/20/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-