ST. JUDE MEDICAL, INC. ENSITE¿ X  EP SYSTEM V1.1.1; COMPUTER, DIAGNOSTIC, PROGRAMMABLE Back to Search Results
Model Number ENSITE-SYSTEM-111
Medical Device Problem Code Electromagnetic Interference (1194)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/30/2022
Type of Reportable Event Malfunction
Event or Problem Description
During the procedure with the patient prepped, metal distortion was noted and the case was cancelled.The table was adjusted, the c-arm, monitor, iv poles, carts and booms were moved.Metal distortion would lower with everything moved away, but increased after several minutes with the equipment still moved away.The case was abandoned with no harm to the patient.
 
Event or Problem Description
This occurred during an atrial flutter ablation procedure.
 
Additional Manufacturer Narrative
The collect logs were provided and reviewed.Review of the files show there were metal distortion errors regarding the prs-a becoming invalid.Adjusting the metal environment near the patient such as raising the flat detector may resolve the issue.Navigate to the prs setup screen and ensure all line items are green.If necessary, resetting metal baseline should resolve the issue.We understand your concerns and will take it under advisement.The software is functioning as designed.See ensite x ep system ifu, setup, system tab - metal sub-tab.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENSITE¿ X  EP SYSTEM V1.1.1
Common Device Name
COMPUTER, DIAGNOSTIC, PROGRAMMABLE
Manufacturer (Section D)
ST. JUDE MEDICAL, INC.
one st. jude medical drive
st. paul MN 55117
Manufacturer (Section G)
ST. JUDE MEDICAL, INC.
one st. jude medical drive
st. paul MN 55117
Manufacturer Contact
janna parks
5050 nathan lane north
plymouth, MN 55442
6517565400
MDR Report Key14015613
Report Number2184149-2022-00095
Device Sequence Number6301540
Product Code DQK
UDI-Device Identifier05415067041722
UDI-Public05415067041722
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K202066
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 04/14/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberENSITE-SYSTEM-111
Device Lot Number8321596
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/31/2022
Supplement Date Received by Manufacturer04/06/2022
04/14/2022
Initial Report FDA Received Date04/05/2022
Supplement Report FDA Received Date04/06/2022
04/14/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured02/17/2022
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexMale
Patient RaceWhite
-
-