ABBOTT GMBH ALINITY C TOTAL BILIRUBIN REAGENT KIT; DIAZO COLORIMETRY, BILIRUBIN Back to Search Results
Model Number 04V5121
Medical Device Problem Code High Test Results (2457)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/10/2022
Type of Reportable Event Malfunction
Event or Problem Description
The customer observed falsely elevated total bilirubin results on alinity c processing module for one patient.The results provided were: on (b)(6) 2022 sid (b)(6) total bilirubin=error message 1041 unable to calculate result total bilirubin dilution 1:3=29, 23, 21, 23 umol/l /1:2 dilution=22, 22, 24 and 22 umol/l laboratory reference range for total bilirubin= normal: 5 to 21 umol/l; slightly high: 21 to 40 umol/l; high: 40 to 257 umol/l; critical: 257 to 2138 umol/l there was no reported impact to patient management.
 
Additional Manufacturer Narrative
An evaluation is in process.A follow-up report will be submitted when the evaluation is complete.
 
Additional Manufacturer Narrative
The complaint evaluation included a review of data and information provided by the customer, search for similar complaints, ticket trending review, labeling review, device history record review for alinity c total bilirubin reagent ln 04v51-21, lot number 60494uq09.The trending report review determined that there are no trends for the product for the complaint issue.Return testing was not completed as returns were not available.Device history record review did not identify any non-conformances or deviations with the likely cause lot(s) and complaint issue.The customer confirmed there were no issues with any other specimens and quality controls were in range.No additional issues were identified.A review of the manufacturing documentation did not identify any issues associated with the customer's observation.A review of the product labeling concluded that the issue is sufficiently addressed.Based on the investigation no product deficiency was identified for the alinity c total bilirubin reagent, lot number 60494uq09.Updated section d4 device expiration: date to 2/28/2023 from 9/30/2022.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ALINITY C TOTAL BILIRUBIN REAGENT KIT
Common Device Name
DIAZO COLORIMETRY, BILIRUBIN
Manufacturer (Section D)
ABBOTT GMBH
max-planck-ring 2
wiesbaden 65205
GM  65205
Manufacturer (Section G)
ABBOTT GMBH
max-planck-ring 2
wiesbaden 65205
GM   65205
Manufacturer Contact
siobhan wright
lisnamuck
post market surveillance
longford N39 E-932
EI   N39 E932
433331157
MDR Report Key14024858
Report Number3002809144-2022-00121
Device Sequence Number19481911
Product Code CIG
UDI-Device Identifier00380740158415
UDI-Public00380740158415
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K121985
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 06/14/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/28/2023
Device Model Number04V5121
Device Catalogue Number04V51-21
Device Lot Number60494UQ09
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 03/16/2022
Supplement Date Received by Manufacturer05/25/2022
Initial Report FDA Received Date04/06/2022
Supplement Report FDA Received Date06/14/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured10/15/2021
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ALNTY C PROCESSING MODU, 03R67-01, AC01936; ALNTY C PROCESSING MODU, 03R67-01, AC01936
Patient SexUnknown
-
-