• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION REZUM; ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION REZUM; ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES Back to Search Results
Model Number G2200
Medical Device Problem Codes Defective Device (2588); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/17/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during a water vapor therapy procedure, the generator worked for 8 seconds before encountering error code 270 (syringe empty).However, the syringe was not empty at all.There was no patient complication due to this event and the procedure was aborted.This event is being reported for aborted/cancelled procedure with a patient under anesthesia.
 
Additional Manufacturer Narrative
Upon receipt of this generator at our quality assurance laboratory, it was thoroughly analyzed.Product analysis identified a damaged internal chassis, a bad wire in the internal delivery device cable and the display screen was flickering.Visual analysis identified minor plastic enclosure damage unlikely related to the reported event.The rest of the generator was in overall good physical condition.Functional testing was unable to replicate the 270 (syringe empty) error fault conditions reported.The review completed on the dhr for this generator confirmed that it met specification prior to release, and the most recent generator inspection found it to be fully functional with no issues.While the device displays 270 syringe empty was not duplicated, the damaged internal chassis and bad wire in the internal delivery device cable components could have contributed to an electrical overstress triggering the error code therefore the reported event is confirmed based on these findings.
 
Event or Problem Description
It was reported that during a water vapor therapy procedure, the generator worked for 8 seconds before encountering error code 270 (syringe empty).However, the syringe was not empty at all.There was no patient complication due to this event and the procedure was aborted.This event is being reported for aborted/cancelled procedure with a patient under anesthesia.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
REZUM
Common Device Name
ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer Contact
alyson harris
4100 hamline avenue north
building c
saint paul, MN 55112
4089353452
MDR Report Key14047173
Report Number2124215-2022-10065
Device Sequence Number4908277
Product Code GEI
UDI-Device Identifier08714729986850
UDI-Public08714729986850
Combination Product (Y/N)N
Initial Reporter StateAL
Initial Reporter CountryUS
PMA/510(K) Number
K180237
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/15/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberG2200
Device Catalogue NumberG2200
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/05/2022
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 03/24/2022
Supplement Date Received by Manufacturer05/31/2022
Initial Report FDA Received Date04/07/2022
Supplement Report FDA Received Date06/15/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/29/2016
Is the Device Labeled for Single Use? (Y/N) No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-