Model Number IPN056682
Medical Device Problem Code Physical Resistance/Sticking (4012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/14/2022
Type of Reportable Event Malfunction
Event or Problem Description
Clinician placed catheter through passage of sheath.He noticed a "grabbing" at the sheath, but still able to pass through until 1/4 advanced length of catheter.He states he met resistance and unable to advance catheter through sheath.At this point he attempted to retract catheter while holding sheath in place.He reported significant difficulty in pulling catheter back out and stated "it was stuck".Procedure aborted.No patient harm reported.No medical intervention required.The patient's condition was reported to be fine.
 
Additional Manufacturer Narrative
(b)(4).
 
Additional Manufacturer Narrative
(b)(4).Complaint verification testing could not be performed as it was reported that the sample is not available for return.A device history record review was performed and no relevant findings were identified.Without the device to evaluate the complaint could not be confirmed and the probable cause could not be determined from the available information.Teleflex will continue to monitor and trend for reports of this nature.
 
Event or Problem Description
Clinician placed catheter through passage of sheath.He noticed a "grabbing" at the sheath, but still able to pass through until 1/4 advanced length of catheter.He states he met resistance and unable to advance catheter through sheath.At this point he attempted to retract catheter while holding sheath in place.He reported significant difficulty in pulling catheter back out and stated "it was stuck".Procedure aborted.No patient harm reported.No medical intervention required.The patient's condition was reported to be fine.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARROW AGBA PICC/DELTA KIT: 5.5 FR X 55 CM
Common Device Name
CATHETER,INTRAVASCULAR,THERAPE
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL DE MEXICO S.A. DE C.V.
ave. washington 3701
colonia panamericana, chihuahua
chihuahua 31200
MX   31200
Manufacturer Contact
katharine tarpley
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key14047432
Report Number9680794-2022-00212
Device Sequence Number11955901
Product Code LJS
UDI-Device Identifier10801902167719
UDI-Public10801902167719
Combination Product (Y/N)N
Initial Reporter StateOH
Initial Reporter CountryUS
PMA/510(K) Number
K122545
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/16/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Expiration Date06/30/2023
Device Model NumberIPN056682
Device Catalogue NumberASK-45552-MHBV
Device Lot Number13F21L0300
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/16/2022
Supplement Date Received by Manufacturer04/30/2022
Initial Report FDA Received Date04/07/2022
Supplement Report FDA Received Date05/03/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured11/13/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-