Model Number NGP680300
Medical Device Problem Code Appropriate Device Problem Term/Code Not Available (3191)
Health Effect - Clinical Codes Corneal Decompensation (1790); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 02/16/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during surgery the physician had some difficulty to maintain a stable chamber.Through follow up we learned that after hydrodissection and initiating of the phacoemulsification with the introduction of the needle, there was no anterior chamber formation that would allow a normal course of surgery.Whenever the pedal was pressed, the chamber did not form and, with the vacuum, it collapsed.All the equipment parameters were in accordance with the standard and recommended.Initially, the handpiece and needle, and later the fluidic were unsuccessfully replaced.The surgeon was able to complete the procedure by using ovd in large quantities.In the end, central anterior vitrectomy was necessary.With prolonged surgical time and insufficient anterior chamber, the patient had a longer and more difficult recovery with significant decompensation of the entire cornea.No further information has been provided.
 
Additional Manufacturer Narrative
Per regulation eu 2016/679 (general data protection regulation), patient identifiers were not collected or recorded and therefore are not available.Telephone number: (b)(6).Device evaluation: the field service engineer (fse) was on site after the event and completed a system checkup.Fse could not duplicate the reported issue.A review of the records related to the device was performed.The system and its components met all specifications prior to being released.As a result of the investigation there is no indication of a product quality deficiency.All pertinent information available to johnson and johnson surgical vision, inc.Has been submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WHITESTAR SIGNATURE
Common Device Name
UNIT, PHACOFRAGMENTATION
Manufacturer (Section D)
AMO MANUFACTURING USA, LLC
510 cottonwood drive
milpitas CA 95035
Manufacturer Contact
somyata nagpal
31 technology drive
irvine, CA 92618
7142478552
MDR Report Key14058437
Report Number3012236936-2022-00899
Device Sequence Number4871635
Product Code HQC
UDI-Device Identifier05050474534476
UDI-Public(01)05050474534476
Combination Product (Y/N)N
Initial Reporter CountryPO
PMA/510(K) Number
K060366
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 04/08/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberNGP680300
Device Catalogue NumberNGP680300
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/11/2022
Initial Report FDA Received Date04/08/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured09/02/2011
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-