Model Number 27040XB
Medical Device Problem Codes Break (1069); Material Separation (1562)
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 03/09/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The ceramic tip fractured/broke from the sheath at end of procedure when pulling out instrument.A missing piece is still in patient.The sheath is over 8 years old.
 
Event or Problem Description
During a turp, surgeon completed the surgery, and realized when pulling out the instruments that a broken piece of ceramic came out.A missing piece is still in the patient.
 
Additional Manufacturer Narrative
An investigation report from kst/mfr.Was received which states: the conclusion and root cause of the non-return product: "the most likely cause is the age ( 8 years) of the item and the high" application cycles.This probably caused micro cracks on the ceramic beak, which led to the breakage of the beak during extraction.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INNER CERAMIC INSULATION TUBE
Common Device Name
RESECTOSCOPE SHEATH, INNER FIXED SHEATH
Manufacturer (Section D)
KARL STORZ SE & CO. KG
dr.-karl-storz-strasse 34
78532
tuttlingen, gm,
GM 
Manufacturer (Section G)
KARL STORZ SE & CO.KG
dr.-karl-storz -strasse 34
78532
tuttlingen, gm,
GM  
Manufacturer Contact
anja fair
2151 e. grand avenue
el segundo 
MDR Report Key14084349
Report Number9610617-2022-00031
Device Sequence Number5289310
Product Code FBO
UDI-Device Identifier04048551076569
UDI-Public4048551076569
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K943668
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 11/16/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number27040XB
Device Catalogue Number27040XB
Device Lot NumberNV01
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/14/2022
Supplement Date Received by Manufacturer03/14/2022
Initial Report FDA Received Date04/12/2022
Supplement Report FDA Received Date11/16/2022
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured01/01/2014
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexMale
-
-