MAUDE Adverse Event Report: INARI MEDICAL, INC. CLOTTRIEVER CATHETER; THROMBECTOMY SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

INARI MEDICAL, INC. CLOTTRIEVER CATHETER; THROMBECTOMY SYSTEM Back to Search Results
Model Number 40-102
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Bradycardia (1751); Cardiac Arrest (1762); High Blood Pressure/ Hypertension (1908); Cardiogenic Shock (2262); Low Oxygen Saturation (2477)
Date of Event 03/17/2022
Type of Reportable Event Death
Additional Manufacturer Narrative
The inari devices were discarded by the user facility and are not available for evaluation.The device identifiers were not provided; however, the company recorded all lots shipped to the facility and each of the possible lot history records were reviewed.There were no discrepancies or unusual findings.Based on the information reviewed, there is no evidence to indicate the presence of a potential quality issue with respect to manufacturing, design, or labeling.The case was reviewed by inari's chief medical officer, who concluded that the patient's death was the result of right heart failure.The relationship between the event and the inari devices is not known, but there is no evidence of use error or device malfunction.Cardiovascular collapse and patient deterioration are identified in the device labeling as potential complications / adverse events.This mdr is for the clottriever catheter device.Refer to mdr #3011525976-2022-00005 for the other inari device involved in this event.Manufacturer reference #: (b)(4).
 
Event or Problem Description
A (b)(6)-year-old male patient with a rare blood clotting disorder presented to the emergency department in unstable condition with clotting above his existing inferior vena cava (ivc) filter.The patient also had bilateral deep vein thrombosis (dvt) in both legs.The ivc filter was placed 9 days prior and the patient underwent spinal surgery 5 days prior.The computerized tomography (ct) scan did not show a pulmonary embolism.Anticoagulant medication had been discontinued since the time of ivc filter placement and was not reinitiated.The treatment plan was to use the inari flowtriever 20 (t20) to address clotting above and in the ivc filter and then use the inari clottriever to address the dvts in the legs.An echocardiogram was not performed prior to the procedure.An activated clotting time (act) test was run and the advising neurosurgeon requested limiting anticoagulants.The patient was intubated and placed on vasopressors.A 22 fr gore dryseal sheath was placed in the neck and an 8 fr sheath was placed in the left popliteal vein.Two interventional radiologists were present, the primary physician was assigned to treat the ivc clot with the t20 and the second physician provided assistance and assigned to use the angiojet to treat the dvts in the left external and common iliac.The t20 was positioned above the ivc filter and the first pass yielded a large amount of clot.Three subsequent passes of the t20 were made below and in the filter.The third pass cleared a large amount of procedural clot.The t20 was pulled back and flushed.The act reading was 116 and heparin was administered.Imaging revealed clot resolution above the filter, but remaining clot in the filter and ivc.Five more aspirations were performed which addressed the ivc and iliacs, but clot remained in the filter.An attempt was made using the angiojet from below the ivc, along with 2 more aspirations from the t20, but none yielded clot.The physicians changed the plan and decided to use the inari clottriever (ct) to address the dvts in the legs after removing the filter using a long sheath.A 16 fr long sheath was used to remove the ivc filter and the flowtriever (ft) xl discs were deployed above it in the ivc to protect from embolization.The xl ft discs were placed from the left popliteal through the ct sheath.Once the ivc filter was removed from the patient, there was clot adhered to the filter.The ct catheter was then inserted and a single pass was made.At this time, the anesthesiologist informed the treating physicians that the patient was becoming unstable.The patient's right groin was prepped, and a code was initiated, continuing for 21 minutes during which time systemic tpa was administered.Additionally, the physician performed 4 aspirations in the left lung and right lower pulmonary artery, but only 2 small clots were removed.After exhausting all possible interventions, the patient was transferred to the intensive care unit (icu) with a heart rate (hr) of 48 bpm, blood pressure (bp) of 225/132 mmhg, and 50% oxygenation saturation (spo2).Unfortunately, the patient was unable to recover and later expired during the evening.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CLOTTRIEVER CATHETER
Common Device Name
THROMBECTOMY SYSTEM
Manufacturer (Section D)
INARI MEDICAL, INC.
9 parker
suite 100
irvine CA 92618
Manufacturer (Section G)
INARI MEDICAL, INC.
9 parker
suite 100
irvine CA 92618
Manufacturer Contact
kit cariquitan
9 parker
suite 100
irvine, CA 92618
9496008433
MDR Report Key14115860
Report Number3011525976-2022-00006
Device Sequence Number2931935
Product Code QEW
UDI-Device Identifier00850291007093
UDI-Public00850291007093
Combination Product (Y/N)N
Initial Reporter StateUT
Initial Reporter CountryUS
PMA/510(K) Number
K212632
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 04/14/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number40-102
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/17/2022
Initial Report FDA Received Date04/14/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ANGIOJET; CLOTTRIEVER SHEATH; FLOWTRIEVER XL; GORE DRYSEAL SHEATH 22 FR; LONG SHEATH 16 FR; SHEATH 8 FR; TRIEVER20
Outcome Attributed to Adverse Event Life Threatening; Required Intervention; Hospitalization; Death;
Patient Age54 YR
Patient SexMale
-
-