Catalog Number 7D2648
Medical Device Problem Code False Negative Result (1225)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/21/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Additional data: the investigation is still in progress.A supplemental report will be provided after completion.
 
Event or Problem Description
The consumer reported a false negative result with the alere determine hiv 1/2 ag/ab combo 25t test performed on (b)(6) 2022.Pcr confirmation testing generated a positive result.Consumer confirmed that the initial determine combo hiv rapid test gave a negative result, the client was not immediately linked to hiv related medical care within 72 hours of hiv diagnosis and start art.Client's medical care has been delayed pending the result of confirmatory testing thus delaying the start of art.
 
Additional Manufacturer Narrative
Testing was performed at abbott diagnostics scarborough, inc.On retained kit lot 162792 with internal positive quality control samples and negative quality control swabs.All test results were valid and performed as expected.Additionally, the manufacturing records and quality control release testing was reviewed for test kit part number 7d2648 / lot 162792 and test base part number 10732925/ lot 161939.The lot met the required release specifications.A review of the complaints reported as false negative patient results (confirmed and unconfirmed, conflicting results) related to kit lot 162792 showed that the complaint rate is (b)(4).In conclusion, abbott diagnostics scarborough was unable to determine the exact root cause of the reported issue, however it could be attributed to the specific patient sample.The sample may have contained specific substances which may have affected the results.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ALERE DETERMINE HIV 1/2 AG/AB COMBO 25T
Common Device Name
IVD FOR HIV 1/2 AG/AB
Manufacturer (Section D)
ABBOTT DIAGNOSTICS SCARBOROUGH, INC.
10 southgate road
scarborough ME 04074
Manufacturer Contact
rachel blackwell
10 southgate road
scarborough, ME 04074
6613888803
MDR Report Key14120470
Report Number1221359-2022-01715
Device Sequence Number19892167
Product Code MZF
UDI-Device Identifier10811877010293
UDI-Public011081187701029310162792
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
BP120037-0
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 05/17/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Catalogue Number7D2648
Device Lot Number162792
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/21/2022
Supplement Date Received by Manufacturer05/04/2022
Initial Report FDA Received Date04/15/2022
Supplement Report FDA Received Date05/18/2022
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age32 YR
Patient SexFemale
Patient Weight54 KG
Patient EthnicityHispanic
-
-