There were multiple lot numbers reported to be involved.The information for each lot number is as follows: medical device lot #: 21119803; medical device expiration date: 03-nov-2022; device manufacture date: 03-nov-2021.Medical device lot #: 21119800; medical device expiration date: 02-nov-2022; device manufacture date: 02-nov-2021.Medical device lot #: 21129217; medical device expiration date: 03-nov-2022; device manufacture date: 03-nov-2021.Medical device lot #: unknown; medical device expiration date: unknown; device manufacture date: unknown.Investigation summary: 121 unopened lot 21119803, 11 used lot 21119803, 19 used lot 21119800, 1 used lot 21129217, and 48 used unknown lot for model 22003e-07 were returned for investigation by the customer.The sets were examined for defects and abnormalities.No defects or abnormalities were observed.The sets were attached to a cut off bd syringe to see if a fluid path can be observed while the piston is in the activated position.A fluid path was observed while the piston was in the activated position for 57 of the 59 unopened lot 21119803, 9 of the 11 used lot 21119803, 11 of the 19 used lot 21119800, 1 of the 1 used lot 21129217, and 32 of the 48 used unknown lot for model 22003e-07.Of the samples that observed a fluid path, the smartsites were then connected to a 10 ml bd syringe filled with blue dye water and the sets were attempted to be flushed.The sets were successfully flushed.A fluid path was not observed while the piston was in the activated position for 2 of the 59 unopened lot 21119803, 2 of the 11 used lot 21119803, 8 of the 19 used lot 21119800, and 16 of the 48 used unknown lot for model 22003e-07.The smartsites were then connected to a 10 ml bd syringe filled with blue dye water and the sets were attempted to be flushed.The sets were unable to be flushed.The customer complaint that they are not flushing were able to be replicated.A device history record review for model 22003e - 07 lot number 21119803 was performed.The search showed that a total of 8803 units in 1 lot number was built on 03nov2021.There were no quality notifications issued for the failure mode reported by the customer during the production build of this set.A device history record review for model 22003e - 07 lot number 21119803 was performed.The search showed that a total of 17603 units in 1 lot number was built on 13dec2021.There were no quality notifications issued for the failure mode reported by the customer during the production build of this set.Following a small number of similar reports, bd has conducted an in-depth investigation to identify any potential contributing factors for occlusion of this nature.The investigation has determined that a potential contributor could be the result of an insufficient amount of fluorosilicone having been injected into the piston during the assembly process.Fluorosilicone is a lubricant used to ensure proper functioning of the needle-free connector when activated.Due to previous similar reports of this nature bd is currently recommending when encountering needle-free connector flow issues to follow the steps outlined in the attached letter.A trend for this occlusion issue has been identified for this product line.A corrective action preventative action, capa# (b)(4), has been initiated, and a team has been assembled in order to investigate the issue.This incident has been added to our database of reported incidents.Our business team regularly reviews the collected data for identification of emerging trends.
|
|
It was reported that 132 bd alaris¿ smartsite¿ extension sets from lot 21119803, 19 sets from lot 21119800, 1 set from lot 21129217, and 48 sets from an unspecified lot were blocked during the flushing process.The following information was provided by the initial reporter: "they are not flushing and we are constantly running to find a new one and hoping it works.".
|