| Catalog Number |
03.133.008 |
| Medical Device Problem Code |
Device-Device Incompatibility (2919)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
03/22/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
Device report from depuy synthes reports an event in (b)(6) as follows: this is report 2 of 4 for (b)(4).It was reported by the customer in (b)(6) that during an open reduction internal fixation surgery for humeral condyle fracture surgery on (b)(6) 2022, it was observed that an unknown locking screw device did not lock into the fixation plate device after drilling with a threaded guide device (03.133.008).According to the report, the surgeon removed the screw to check the direction and reinserted it but still did not lock.It was reported that the surgeon used drill guide device (03.133.007), and even though he changed direction and drilled, he could not lock it to the plate.It was reported that the event occurred in both the 2nd and 3rd holes from the distal end, so the surgeon tried other screw holes and they were able to lock without problems.Another fixation plate device was used to complete the procedure successfully with 30 minutes of delay.There were no adverse patient consequences nor surgical delay reported.The patient was reported to be in stable condition.No additional information was provided.This report is for one (1) threaded drill guide 2 f/screw 2.7 f/va+ device.This complaint involves four(4) devices.
|
| |
|
Additional Manufacturer Narrative
|
|
The lot number was unknown.Complainant part is not expected to be returned for manufacturer review/investigation.Without a lot number the device history records review could not be completed.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Product was not returned.Based on the information available, it has been determined that no corrective and preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.
|
| |
|
Additional Manufacturer Narrative
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H10: additional narrative: d10, e1 device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
| |
|
Search Alerts/Recalls
|