MAUDE Adverse Event Report: CARDIOVASCULAR SYSTEMS, INC. DIAMONDBACK PERIPHERAL ORBITAL ATHERECTOMY SYSTEM (VIPERWIRE); PERIPHERAL ATHERECTOMY DEVICE (GUIDEWIRE)

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CARDIOVASCULAR SYSTEMS, INC. DIAMONDBACK PERIPHERAL ORBITAL ATHERECTOMY SYSTEM (VIPERWIRE); PERIPHERAL ATHERECTOMY DEVICE (GUIDEWIRE) Back to Search Results
Model Number VPR-GW-EL14
Medical Device Problem Code Material Separation (1562)
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 03/25/2022
Type of Reportable Event Serious Injury
Event or Problem Description
The superficial femoral artery and popliteal were primary wired with a viperwire guide wire, and placement was confirmed on imaging.The treatment area was not tortuous but was highly calcified.One section of the vessel was treated with atherectomy.Thereafter, wire placement was checked and found to be in the desired location.The atherectomy device was advanced, and wire placement was again confirmed to be correct.Treatments were performed with a radial length orbital atherectomy device on low, medium, and high speed.Each treatment time was about 20-25 seconds, and rest time was equal to treatment time.During movement of the oad, the wire migrated into a small side vessel.Atherectomy was then performed in the popliteal vessel.The oad was removed, and wire position was checked on imaging.Placement at that time was observed to be less than ideal.The wire was pulled back, and imaging indicated the wire had fractured.The tip of the wire remained in the side vessel.The remainder of the wire was removed intact.Additional imaging confirmed the wire fragment was in a small side branch and not in the peroneal artery.The opinion of the physician was that the fragment would be "fine" where it was.The physician abandoned the fragment in vivo.
 
Additional Manufacturer Narrative
Device analysis conclusion: the guidewire was received at csi for analysis.Visual examination confirmed the reported fracture.The distal section of the wire was not returned for analysis, which is consistent with details reported to csi.Scanning electron microscopy analysis showed evidence of fatigue with a large ductile tear and folding back onto the core wire.This evidence, along with the fracture location, is consistent with a fracture resulting from the driveshaft spinning too close to the spring tip.It is also possible there was a bend or kink near the spring tip.The root cause of the fracture is considered to be use not consistent with the instructions for use (ifu).The ifu warns, "never advance the orbiting crown to the point of contact with the guide wire spring tip.Distal spring tip detachment and embolization may result.Make sure there is a minimum of 10 cm between the guide wire spring tip and the distal end of the shaft." (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DIAMONDBACK PERIPHERAL ORBITAL ATHERECTOMY SYSTEM (VIPERWIRE)
Common Device Name
PERIPHERAL ATHERECTOMY DEVICE (GUIDEWIRE)
Manufacturer (Section D)
CARDIOVASCULAR SYSTEMS, INC.
1225 old hwy 8 nw
st. paul MN 55112
Manufacturer (Section G)
CARDIOVASCULAR SYSTEMS, INC.
1225 old hwy 8 nw
st. paul MN 55112
Manufacturer Contact
morgan hill
1225 old hwy 8 nw
st. paul, MN 55112
MDR Report Key14186847
Report Number3004742232-2022-00102
Device Sequence Number5795247
Product Code MCW
UDI-Device Identifier10852528005459
UDI-Public(01)10852528005459(17)231130(10)411232-1
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K190634
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 04/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date11/30/2023
Device Model NumberVPR-GW-EL14
Device Catalogue Number7-10035-01
Device Lot Number411232-1
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/29/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/25/2022
Initial Report FDA Received Date04/22/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/06/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age76 YR
Patient SexMale
Patient Weight78 KG
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-