• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: CARDINAL HEALTH 7317 SPG VISTEC 4X4 STR 10'S; GAUZE/SPONGE, INTERNAL, X-RAY DETECTABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CARDINAL HEALTH 7317 SPG VISTEC 4X4 STR 10'S; GAUZE/SPONGE, INTERNAL, X-RAY DETECTABLE Back to Search Results
Model Number 7317
Medical Device Problem Code Material Separation (1562)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/05/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
An investigation is currently underway.Upon completion, the results will be forwarded.
 
Event or Problem Description
The customer reported that they received a call from the operating room and the gauze is shredding when being used on the patient.
 
Additional Manufacturer Narrative
The device history record (dhr) was reviewed.For sterilized products, the dhr and the sterilization documents undergo further review prior to release to the distribution center.Prior to a lot¿s release, the lots must be deemed acceptable by passing inspections that are based on a valid sampling plan.Inspectors routinely examine a statistical sample both physically and visually.The reported lot met all the defined acceptance requirements and was released.Inspection records show no failures.On evaluation of the sample, minor fraying could be seen.The reported condition was confirmed.The root cause was determined to be the set screws for the heat roller on the machine were loose.Corrective action performed was the manufacturing associates involved with the process to produce this product have been made aware of the issue and are to be alert to this kind of issue.Samples were sent to the production associates for further awareness and the quality impact to our customers.The set screws for the heat roller on the machine are being monitored for looseness.This complaint will be recorded for tracking and trending purposes.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
7317 SPG VISTEC 4X4 STR 10'S
Common Device Name
GAUZE/SPONGE, INTERNAL, X-RAY DETECTABLE
Manufacturer (Section D)
CARDINAL HEALTH
1430 marvin griffin road, po b
augusta GA 30906
Manufacturer (Section G)
CARDINAL HEALTH
1430 marvin griffin road, po b
augusta GA 30906
Manufacturer Contact
jill saraiva
777 west street
mansfield, MA 02048
5086183640
MDR Report Key14197004
Report Number1018120-2022-00464
Device Sequence Number4446995
Product Code GDY
UDI-Device Identifier10884527016990
UDI-Public10884527016990
Combination Product (Y/N)N
Initial Reporter StateVA
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 05/23/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model Number7317
Device Catalogue Number7317
Device Lot Number21H032762
Is the Reporter a Health Professional? No
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 04/05/2022
Supplement Date Received by Manufacturer04/05/2022
Initial Report FDA Received Date04/25/2022
Supplement Report FDA Received Date05/23/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device A
Patient Sequence Number1
Patient SexUnknown
-
-