DATASCOPE CORP. - MAHWAH CS100 INTRA-AORTIC BALLOON PUMP, SPANISH, 220V; SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL Back to Search Results
Model Number 0998-00-3013-58
Medical Device Problem Code Device Contamination with Body Fluid (2317)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/29/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Testing of actual/suspected device: a getinge field service engineer (fse) was dispatched to evaluate the iabp and confirmed blood in the unit and needs to replace the safety disk, crm assembly, blood detect tubing, purge valve assembly, fill manifold assembly, bracket fill manifold, transducer block assembly, male luer, polyurethane tubing, reservoir assembly, barb hose fitting, cable clamp, and the insulator drive manifold.Additional information is being requested with regard to the repair and status of the iabp.A supplemental report will be submitted upon completion of our investigation.
 
Event or Problem Description
It was reported that the cs100 intra-aortic balloon pump (iabp) had a blood stop error.It is unknown the circumstances under which the event occurred.It is also unknown if there was a patient involvement.However, there was no adverse event reported.
 
Additional Manufacturer Narrative
Updated fields: b4, g3, g6, g7, h2, h4, h6, h10, h11 corrected fields: d5, e3 a getinge field service engineer (fse) was dispatched to investigate the issue.To fix the issue, the fse located the affected parts due to the blood back and replaced them.The fse then adjusted the unit and verified that the unit was functioning correctly.The fse also confirmed the unit was returned to the customer in cleared for clinical use.
 
Event or Problem Description
N/a.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CS100 INTRA-AORTIC BALLOON PUMP, SPANISH, 220V
Common Device Name
SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL
Manufacturer (Section D)
DATASCOPE CORP. - MAHWAH
1300 macarthur blvd
mahwah NJ
Manufacturer (Section G)
DATASCOPE CORP. - MAHWAH
1300 macarthur blvd
mahwah NJ
Manufacturer Contact
arelean guzman
1300 macarthur blvd
mahwah, NJ 
MDR Report Key14208283
Report Number2249723-2022-00930
Device Sequence Number1841522
Product Code DSP
UDI-Device Identifier10607567107622
UDI-Public10607567107622
Combination Product (Y/N)N
Initial Reporter CountrySP
PMA/510(K) Number
K031636
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
Report Date (Section B) 07/26/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0998-00-3013-58
Device Catalogue Number0998-00-3013-58
Device Lot NumberN/A
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/29/2022
Supplement Date Received by Manufacturer07/26/2023
Initial Report FDA Received Date04/26/2022
Supplement Report FDA Received Date07/26/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/28/2006
Is the Device Labeled for Single Use? (Y/N) No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-