• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SMITH & NEPHEW, INC. EMP STEM 9 SO 140MM; PROSTHESIS, HIP, SEMI-CONSTRAINED, UNCEMENTED, METAL/POLYMER, NON-POROUS, CALICU

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SMITH & NEPHEW, INC. EMP STEM 9 SO 140MM; PROSTHESIS, HIP, SEMI-CONSTRAINED, UNCEMENTED, METAL/POLYMER, NON-POROUS, CALICU Back to Search Results
Model Number 71290902
Medical Device Problem Codes Fracture (1260); Loosening of Implant Not Related to Bone-Ingrowth (4002)
Health Effect - Clinical Codes Failure of Implant (1924); Pain (1994); Loss of Range of Motion (2032); Deformity/ Disfigurement (2360); Implant Pain (4561)
Date of Event 09/13/2021
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that, after a right thr on (b)(6) 2015 due to right hip osteoarthritis with limited range of motion, the patient experienced pain, groin tenderness, limited internal and external rotation.Ct scan showed prosthetic fracture of stem and x-rays confirmed broken stem displaced, fractured, and angulated at the level of the greater trochanter/intertrochanteric region.The patient underwent revision surgery on right hip on (b)(6) 2021.It is unknown the status of the patient.
 
Additional Manufacturer Narrative
Internal complaint reference: case(b)(4).
 
Additional Manufacturer Narrative
Internal complaint reference number: (b)(4).
 
Additional Manufacturer Narrative
H3, h6: the device was not returned for evaluation and the reported event could not be confirmed.The clinical/medical investigation concluded that, smith and nephew has not received the explanted devices or adequate patient-specific materials to fully evaluate the complaint, but if additional clinically relevant materials are later received, then the case may be re-opened for further evaluation.A review of the manufacturing records did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.A review of complaint history for the part number over the past 12 months and for the batch number based on historical data of the device did not reveal similar events for the listed device.A review of the instructions for use documents for hip systems revealed that implant fracture has been identified as a adverse events in primary and revision surgery.A review of the risk management file revealed this failure mode was previously identified.The anticipated risk level is still adequate.A historical review concluded that there are no prior actions related to this product and event.At this time, we have no reason to suspect that the product failed to meet any product specifications at the time of manufacture.Some potential probable causes for this event could include but not limited to traumatic injury or surgical technique.The contribution of the device to the reported event could not be corroborated.Based on this investigation, the need for corrective action is not indicated.Without the return of the actual product involved, our investigation could not proceed.Should the device or additional information be received, the complaint will be reopened.No further investigation is warranted for this complaint; however, we will continue to monitor for future complaints and investigate as necessary.We consider this investigation closed.
 
Additional Manufacturer Narrative
H3, h6: the associated device was returned and evaluated.The visual inspection revealed complete fracture of the stem.A laboratory analysis performed on the device revealed bony ingrowth on proximal portion of femoral stem with possible extraction damage.No deviations from processing or material specifications were noted for any of the components.From visual observation and information provided, no conclusions can be made as to what initiated the fatigue fracture.The clinical/medical investigation concluded that, the provided x-rays were reviewed, confirm the reported prosthetic fracture of stem.The clinical root cause of the reported stem fracture cannot be definitively concluded; however, the reported rollover golf cart accident can¿t be ruled out as a contributing factor to the prosthetic fracture of stem and subsequent revision.At 2-months post revision it was noted, the patient was doing very well.No further clinical assessment is warranted at this time.A review of the production order did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.A review of complaint history for the part number over the past 12 months and for the batch number based on historical data of the device did not reveal similar events for the listed device.A review of the instructions for use documents for total hip systems revealed implant fracture as a probable cause of patients who are young, physically active, and/or heavy, this has been identified as adverse events in primary and revision surgery.A review of the risk management file revealed this failure mode was previously identified.The anticipated risk level is still adequate.A historical review concluded that there are no prior actions related to this product and event.According with the inspection procedure, the final inspection includes the verification of part configuration per print.At this time, we have no reason to suspect that the product failed to meet any specifications at the time of manufacture.A factor that could contribute to the reported event include traumatic injury.Based on this investigation, the need for corrective action is not indicated.Should additional information be received, the complaint will be reopened.No further investigation is warranted for this complaint; however, we will continue to monitor for future complaints and investigate as necessary.We consider this investigation closed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EMP STEM 9 SO 140MM
Common Device Name
PROSTHESIS, HIP, SEMI-CONSTRAINED, UNCEMENTED, METAL/POLYMER, NON-POROUS, CALICU
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
Manufacturer (Section G)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key14212753
Report Number1020279-2022-01979
Device Sequence Number11857943
Product Code MEH
UDI-Device Identifier03596010561275
UDI-Public03596010561275
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
K052426
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Device Explanted Year2021
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 03/20/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/08/2023
Device Model Number71290902
Device Catalogue Number71290902
Device Lot Number13BM16882A
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/31/2022
Supplement Date Received by Manufacturer04/28/2022
05/30/2022
03/16/2023
Initial Report FDA Received Date04/26/2022
Supplement Report FDA Received Date05/16/2022
05/30/2022
03/20/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured06/10/2013
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
COCR 12/14 FEM HEAD 32 + 0, 14LM09267; COCR 12/14 FEM HEAD 32 + 0,14LM09267; COCR 12/14 FEM HEAD 32 + 0-14LM09267; EMP SLV 9 SM CONE 2 SPOUT, 14GSL0014A; EMP SLV 9 SM CONE 2 SPOUT, 14GSL0014A; EMP SLV 9 SM CONE 2 SPOUT-13BM16882A; PRO NON-POR TB BASE RT S3, 10AM10691; R3 0 DEGREE XLPE LNR 32MM X 54MM, 15AM06290; R3 0 DEGREE XLPE LNR 32MM X 54MM,15AM06290; R3 0 DEGREE XLPE LNR 32MM X 54MM-15AM06290; R3 0 HOLE ACET SHELL 54MM, 15AM06290; R3 0 HOLE ACET SHELL 54MM, 15AM06290; REF THREADED HOLE COVER; REF THREADED HOLE COVER, 14LM09267; REF THREADED HOLE COVER, 14LM09267
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient Age61 YR
Patient SexMale
-
-