Catalog Number 318-02
Device Problem Deformation Due to Compressive Stress (2889)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 04/04/2022
Event Type  malfunction  
Event Description
It was reported that the arctic sun device was receiving an alert 113 (reduced water temperature control). Patient was placed with neonatal arctic gel pad in rewarm mode. Target temperature was 36. 5 c, patient temperature was 36. 1 c, water temperature was 33 c, flow rate was 0. 6lpm, water reservoir level was 2 bars, pump hours were 164, system hours were 248, heater command was 19 percent and mixing pump command was 0 percent. Patient weighed 6. 5 kilograms. Mss walked nurse through disconnecting and reconnecting arctic gel pad, nurse checked for kinks and noted slight kink in pad tubing. Once straightened out nurse stated that the flow rate went up to 0. 8lpm. Nurse stated they already noticed that flow rate was better and would call back if they received any other alerts or alarms for further diagnostics.
 
Manufacturer Narrative
The investigation is still in progress. Once the investigation is complete a supplemental report will be filed. The device was not returned.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameARCTIC SUN® TEMPERATURE MANAGEMENT SYSTEM, ARCTICGEL¿ PADS
Type of DeviceARCTIC GEL PADS
Manufacturer (Section D)
MEDIVANCE, INC. ¿ 1725056
321 s taylor ave
suite 200
louisville 80027
Manufacturer (Section G)
MEDIVANCE, INC. ¿ 1725056
321 s taylor ave
suite 200
louisville 80027
Manufacturer Contact
juan velez
8195 industrial blvd
covington 30014
7707846100
MDR Report Key14239966
MDR Text Key290382028
Report Number1018233-2022-03104
Device Sequence Number1
Product Code DWJ
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K142702
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Health Professional,User Facility
Reporter Occupation
Type of Report Initial,Followup
Report Date 07/21/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/28/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Catalogue Number318-02
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received07/21/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 04/28/2022 Patient Sequence Number: 1
-
-