| Model Number |
95834 |
| Medical Device Problem Codes |
Off-Label Use (1494); Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Nodule (4551)
|
| Date of Event |
11/09/2017
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Health professional reported in the article ¿a retrospective review of the safety and efficacy of low-dose triamcinolone mixed with hyaluronic acid fillers to reduce post-injection infraorbital swelling¿ that 19 patients were injected with juvéderm volbella® xc and seven patients with juvéderm® vollure¿ xc experienced swelling.One patient injected with juvéderm volbella® xc experienced ¿granulomas¿ that resolved completely without further adverse events once they were injected with hyaluronidase.Biopsy was not provided.
|
| |
|
Additional Manufacturer Narrative
|
|
The filler was injected into the patient and is not accessible for return.The syringe was not returned for evaluation.Clarification to implant date: 447 patients who underwent 706 infraorbital hyaluronic acid filler treatments from (b)(6) 2013 to (b)(6) 2020 by a single injector.Article citation: siperstein, robyn.Et al."a retrospective review of the safety and efficacy of low-dose triamcinolone mixed with hyaluronic acid fillers to reduce post-injection infraorbital swelling." j clin aesthet dermatol.2022 apr;15(4):13-19.A request for further information have been made.Allergan has received no response from the authors.The event is a physiological complication and analysis of the device generally does not assist allergan in determining a probable cause for this event.This is a known potential adverse event addressed in the product labeling.
|
| |
|
Event or Problem Description
|
|
Additionally, in the article "a retrospective review of the safety and efficacy of low-dose triamcinolone mixed with hyaluronic acid fillers to reduce post-injection infraorbital swelling" also noted patient was injected into the tear troughs and mixing low-dose triamcinolone with juvéderm® (off-label usage).This is the same article reported under mdr id#: 3005113652-2022-00287 (allergan complaint#: (b)(4).This mdr is being submitted for the suspect product, juvéderm volbella® xc.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional, changed, and/or corrected data.
|
| |
|
Event or Problem Description
|
|
Additionally, the healthcare professional reported injecting the patient under the eyes with 1 cc of juvéderm volbella® xc.The patient was pre-treated with blt (20%, 10%, 6%) and was given ice post-treatment.Adverse event occurred three months post-injection at the injection site.The patient was treated with hylenex.2 cc/5-fu 0.4/lidocaine with epi 0.1cc 6 days later, again 4 days later, again a month later, again half a month later, and once more 13 days later.The event resolved the following month.
|
| |
|
Additional Manufacturer Narrative
|
|
A review of the device history record has been initiated.If any new, changed or corrected information is noted, a supplemental medwatch will be submitted.
|
| |
|
Additional Manufacturer Narrative
|
|
A review of the device history record has been completed.No deviations or non-conformances noted.
|
| |
|
Event or Problem Description
|
|
Health professional reported in the article ¿a retrospective review of the safety and efficacy of low-dose triamcinolone mixed with hyaluronic acid fillers to reduce post-injection infraorbital swelling¿ that 19 patients were injected with juvéderm volbella® xc and seven patients with juvéderm® vollure¿ xc experienced swelling.One patient injected with juvéderm volbella® xc experienced ¿granulomas¿ that resolved completely without further adverse events once they were injected with hyaluronidase.Biopsy was not provided.
|
| |
|