Model Number 7K76-25
Medical Device Problem Code High Test Results (2457)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/01/2020
Type of Reportable Event Malfunction
Event or Problem Description
The customer questioned architect prolactin results for one patient.The customer noted the patient was tested 4-5 times from 2020- 2022 with prolactin ranging from 70-100 ng/l and sids (b)(6).At one point the customer reported result of 96.2 out of the lab- while total prolactin on the same sample from another lab was 31ng/l (external lab has a similar ref range) with a macroprolactin result of 0.421 (positive macroprolactin stated at >0.4).The patient is asymptomatic but has been subjected to pituitary imaging (mri) with contrast due to the results, which didn¿t show any anomalies, and has been followed up on numerous occasions by the endocrine clinic.The patient did not suffer any adverse effects from the mri and was noted as having no symptoms of hyperprolactinemia at all.The high prolactin was picked up incidentally on labs ordered by primary care several years ago.The patient was noted to have some features of pcos, and per the physician the mildly elevated prolactin from icl would be much more in keeping with that presentation rather than the values between 70-100 ug/l.No impact to patient management was reported.
 
Additional Manufacturer Narrative
Multiple sids were provided for the same patient.An evaluation is in process.A follow-up report will be submitted when the evaluation is complete.
 
Additional Manufacturer Narrative
The complaint investigation included a review of data and information provided by the customer, search for similar complaints, ticket trending review, labeling review, device history record review, and field data review.Return testing was not completed as returns were not available.Data and information provided by the customer were reviewed and support the complaint issue without indication for any additional issue.Ticket and trending review did not identify any trends.Device history review did not identify any non-conformances or deviations with the complaint list number.The overall performance of the architect prolactin reagents in the field was reviewed using data gathered from customers worldwide.The median population result for all lots falls within 2sd indicating the lot is performing acceptably.Labeling was reviewed and sufficiently addresses the customer¿s issue.Based on the investigation, no systemic issue or deficiency of the architect prolactin reagent was identified.Corrected information in section d3-email and g1-mfg site email.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARCHITECT PROLACTIN REAGENT KIT
Common Device Name
RADIOIMMUNOASSAY, PROLACTIN (LACTOGEN)
Manufacturer (Section D)
A.I.D.D LONGFORD
lisnamuck
co. longford
longford N39E9 32
EI  N39E932
Manufacturer (Section G)
A.I.D.D LONGFORD
lisnamuck
co. longford
longford N39E9 32
EI   N39E932
Manufacturer Contact
siobhan wright
lisnamuck
post market surveillance
longford N39 E-932
EI   N39 E932
433331157
MDR Report Key14282371
Report Number3005094123-2022-00091
Device Sequence Number14739964
Product Code CFT
UDI-Device Identifier00380740014865
UDI-Public00380740014865
Combination Product (Y/N)N
Initial Reporter CountryCA
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 06/24/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number7K76-25
Device Catalogue Number07K76-25
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 04/20/2022
Supplement Date Received by Manufacturer06/24/2022
Initial Report FDA Received Date05/04/2022
Supplement Report FDA Received Date06/24/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ARC I2000SR INST, 03M74-02, ISR52296.; ARC I2000SR INST, 03M74-02, ISR52296.
Patient SexUnknown
-
-