ETHICON INC. SFX SPI MCRYL+ UNI 27IN 3-0 SA PS-2 PRM; SUTURE, SURGICAL, ABSORBABLE, POLYGLCOLIC ACID Back to Search Results
Model Number SXMP1B109
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/04/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Product complaint # (b)(4).This is a combination product, and the event has been reviewed for both the suture and the triclosan.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Additional information was requested, and the following was obtained via: fixation tab or loop breakage during the procedure or barbs are missing and not holding in the tissue during the procedure? loop was broken.Do you have a picture for visual analysis? yes, have attached a picture.Was needle removed from the patient? needle did not go in the patient.Any additional tissue dissection damage due to searching for needle? no, the needle did not break inside the patient.It broke when they grabbed it with the needle driver.What was the size of the needle used? ct-2.Was more than half the needle retained in the patient? no needle in patient lot number? no.Trade name - irgacare®, active ingredient(s) ¿ triclosan, dosage form ¿ suture/solid/parenteral, strength ¿ = 2360 g/m.Events reported: 2210968-2022-03277 and 2210968-2022-03278.
 
Event or Problem Description
It was reported that a patient underwent a spine procedure (b)(6) 2022 and barbed suture was used.During the procedure, multiple sutures had 'needles breaking in half and ends not holding.No adverse patient consequences were reported.Additional information was requested.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SFX SPI MCRYL+ UNI 27IN 3-0 SA PS-2 PRM
Common Device Name
SUTURE, SURGICAL, ABSORBABLE, POLYGLCOLIC ACID
Manufacturer (Section D)
ETHICON INC.
1000 route 202
raritan NJ 08869
Manufacturer (Section G)
ETHICON INC.-SAN LORENZO PR
road 183, km. 8.3
san lorenzo PR
*  
Manufacturer Contact
elba bello
1000 route 202
raritan, NJ 08869
MDR Report Key14286585
Report Number2210968-2022-03276
Device Sequence Number1519704
Product Code GAM
UDI-Device Identifier10705031236608
UDI-Public10705031236608
Combination Product (Y/N)Y
Initial Reporter CountryUS
PMA/510(K) Number
N12159
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 05/04/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model NumberSXMP1B109
Device Catalogue NumberSXMP1B109
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/05/2022
Initial Report FDA Received Date05/05/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-