MAUDE Adverse Event Report: SMITH & NEPHEW, INC. POROUS FEMORAL COMP SIZE 5-RIGHT MEDIAL; PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, UNICOMPARTMENTAL/UNICONDYLAR,

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SMITH & NEPHEW, INC. POROUS FEMORAL COMP SIZE 5-RIGHT MEDIAL; PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, UNICOMPARTMENTAL/UNICONDYLAR, Back to Search Results
Catalog Number 1-10003-500
Medical Device Problem Code Malposition of Device (2616)
Health Effect - Clinical Codes Discomfort (2330); Deformity/ Disfigurement (2360)
Date of Event 01/20/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Internal complaint reference: (b)(4).
 
Event or Problem Description
It was reported that, after a right unicompartmental knee arthroplasty had been performed on (b)(6) 2021, the patient began experiencing some discomfort.Postoperative x-rays performed during follow up showed the tibia collapsed anteriorly into valgus with "blow-out" of medial tibial.The surgeon stated that the femoral component was placed more medially than desired due to pre-existing tibia vara deformity, leading to edge loading on the tibia.A revision surgery was performed on (b)(6) 2022 to treat this adverse event.During this procedure, the surgeon decided to remove all the elements from the prosthesis construct and replace them with a full tka system.The patient's outcome is unknown.
 
Additional Manufacturer Narrative
Section h3, h6: the device was not returned for evaluation but the provided imaging shows a pre-op tibial deformity, post-partial knee femoral component overhang, and a medial valgus collapse.The clinical/medical investigation concluded that, based on the information provided, the use of the components in a knee with a pre-op varus deformity is contraindicated.Additionally, the ifu addresses risks factors which may cause excessive loading and challenges within certain clinical contexts.Therefore, the surgeon¿s conclusion of contraindicated/patient selection, surgical technique issues with mal-positioning of femur (edge loading), and the abnormally high level of activity/post-op loading were most likely the contributing factors to the reported tibial collapse/fracture with malrotation of the tibial component.Of note, education/training actions are anticipated in order to mitigate similar events in the future.The patient impact beyond the reported discomfort, tibial collapse and subsequent revision/conversion to tka cannot be determined.No further clinical/medical assessment can be rendered at this time.A review of the manufacturing records did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.A review of complaint history for the part number over the past 12 months and for the batch number based on historical data of the device did not reveal similar events for the listed device.A review of the instructions for use documents for engage partial knee system revealed that uncontrolled varus/valgus has been identified as a postoperative adverse effect.A review of the risk management file revealed this failure mode was previously identified.The anticipated risk level is still adequate.A historical review concluded that there are prior actions related to this product and event: corrective and preventive actions are being performed to reduce the risk of a revision surgery from happening.At this time, we have no reason to suspect that the product failed to meet any product specifications at the time of manufacture.Possible causes could include but not limited to contraindicated/patient selection, surgical technique issues with mal-positioning of femur (edge loading) and abnormally high level of activity/post-op.The contribution of the device to the reported event could be corroborated since a conversion to tka was required.Based on this investigation, the need for corrective action is not indicated.Should the device or additional information be received, the complaint will be reopened.No further investigation is warranted for this complaint; however, we will continue to monitor for future complaints and investigate as necessary.We consider this investigation closed.
 
Additional Manufacturer Narrative
Section h3, h6: the device was not returned for evaluation; therefore, a device analysis could not be performed.The clinical/medical investigation concluded that, based on the information provided, the use of the components in a knee with a pre-op varus deformity is contraindicated.Additionally, the instructions for use addresses risks factors which may cause excessive loading and challenges within certain clinical contexts.Therefore, the surgeon¿s conclusion of contraindicated/patient selection, surgical technique issues with mal-positioning of femur (edge loading), and the abnormally high level of activity/post-op loading were most likely the contributing factors to the reported tibial collapse/fracture with malrotation of the tibial component.Of note, education/training actions are anticipated in order to mitigate similar events in the future.The patient impact beyond the reported discomfort, tibial collapse and subsequent revision/conversion to total knee arthroplasty cannot be determined.No further clinical/medical assessment can be rendered at this time.A review of the production records did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.A review of complaint history for the part number and for the batch number based on historical data did not reveal similar events for the listed device.A review of the instructions for use documents for engage partial knee system revealed in contraindications that unicompartmental replacement is contraindicated in patients who have a permanent valgus or varus deformity that requires correction for the knee to function satisfactorily post-op.There is not enough data available to conclude that the overall clinical benefit outweighs the potential risk profile when compared to the state of the art.The existing data identifies a potential signal that the performance is an outlier vs the state of the art with respect to the risk for revision.In addition, a historical review concluded that no previous escalated actions for this type of issue were identified.However, as a correction action a voluntary market removal will be performed for the engage cementless partial knee system due recent complaint data that indicates that the revision rate may be trending higher than corresponding similar devices in global joint replacement registries.At this time, we have no reason to suspect that the product failed to meet any specifications at the time of manufacture.Factors that could contribute to the reported event include contraindicated/patient selection, surgical technique issues with mal-positioning of femur (edge loading), and the abnormally high level of activity/post-op loading.Based on this investigation, the need for corrective action may be indicated.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POROUS FEMORAL COMP SIZE 5-RIGHT MEDIAL
Common Device Name
PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, UNICOMPARTMENTAL/UNICONDYLAR,
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
Manufacturer (Section G)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key14332802
Report Number1020279-2022-02248
Device Sequence Number12105760
Product Code NJD
UDI-Device Identifier00885556873007
UDI-Public885556873007
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
K190439
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Device Explanted Year2022
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Remedial Action Recall
Type of Report Initial,Followup,Followup
Report Date (Section B) 07/05/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/07/2025
Device Catalogue Number1-10003-500
Device Lot Number100012
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/10/2022
Supplement Date Received by Manufacturer06/17/2022
06/30/2023
Initial Report FDA Received Date05/09/2022
Supplement Report FDA Received Date06/21/2022
07/05/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured05/07/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
RES92286 AND Z-1670-2023
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
TIBIAL ANCHOR STEM SIZE 3-4-100070; TIBIAL INSERT SIZE 4-RIGHT MED 9MM-100092
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient Age51 YR
Patient SexMale
Patient Weight77 KG
-
-