This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by depuy mitek or its employees that the report constitutes an admission that the device, depuy mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Investigation summary :the clear cannula-threaded was returned to mitek for evaluation.Mitek then conducted visual inspection of device received.Upon visual inspection, the packaging was not received for evaluation.The clearcannula-threaded and a component were analyzed.Based on the manufacturer information, the component received does not belong to the device.No anomalies and broken condition were found.Silicon oil was found inside the obturator and cannula guard.A manufacturing record evaluation was performed for the finished device lot number: 2101244, and no non-conformances related to the reported complaint condition were identified.Based on the visual evaluation of the device received and no further information available, this complaint cannot be confirmed, and we cannot determine what caused the user to experience the reported event.A manufacturing investigation was performed; as a result, during the product packaging process, the operator will 100% visual inspection, please refer to the below table for our visual inspection criteria.Qc is sampling based on the process control map (pcm) definition to monitor the packaging process (before and during operation, the inspection of the seal and pouch).According to the drawing, the tip of the obturator will uniformly stick the silicone oil for the lubricating effect, this consist in the condition of the device.The package in the photo is not from our product package and based on the drawing, there are no additional components in our product.Nevertheless, there is no evidence of manufacturing anomalies.As part of mitek¿s quality process all devices are manufactured, inspected, and released to approved specifications.At this point in time, no corrective action is required, and no further action is warranted.However, depuy synthes mitek will continue to track any related complaints within this device family as a means of monitoring the extent with which this complaint is observed in the field.
|
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by depuy mitek or its employees that the report constitutes an admission that the device, depuy mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.The actual device has been returned and is currently pending evaluation.Once reliability engineering evaluates the device, a supplemental medwatch report will be sent accordingly.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|