| Model Number |
22003E-07 |
| Medical Device Problem Code |
Complete Blockage (1094)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
04/20/2022
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
|
| |
|
Event or Problem Description
|
|
It was reported that at least one bd alaris smartsite extension set was clogged.The following information was provided by the initial reporter: we've had several failed extension sets.
|
| |
|
Event or Problem Description
|
|
It was reported that at least one bd alaris smartsite extension set was clogged.The following information was provided by the initial reporter: we've had several failed extension sets.
|
| |
|
Additional Manufacturer Narrative
|
|
The following fields were updated due to additional information: d.4.Medical device lot #: 21089080; d.4.Medical device expiration date: 31-aug-2022; h.4.Device manufacture date: 31-aug-2021; d.4.Medical device lot #: 21129217; d.4.Medical device expiration date: 31-aug-2022; h.4.Device manufacture date: 31-aug-2021.D.9.Device available for eval?: yes.D.9.Returned to manufacturer on: 29-apr-2022.H.6.Investigation: 10 samples model 22003e - 07 were returned for investigation( 3 used, 1 unused samples lot21089080 and 6 unused samples lot21129217).The sets were examined for defects and abnormalities.No defects or abnormalities were observed.The set was attached to a cut off bd syringe to see if a fluid path can be observed while the piston is in the activated position.A fluid path was observed while the piston was in the activated position for all but 1 used sample lot21089080.The smartsites were then connected to a 10 ml bd syringe filled with blue dye water and the sets were attempted to be flushed.All sets were successfully flushed except for 1 used lot 21089080 sample.The customer complaint that the extension sets failed could be replicated for one of the returned samples.The root cause is unknown.A device history record review for model 22003e - 07 lot number 21089080 was performed.There were no quality notifications issued for the failure mode reported by the customer during the production build of this set.A device history record review for model 22003e - 07 lot number 21129217 was performed.There were no quality notifications issued for the failure mode reported by the customer during the production build of this set.A trend for this occlusion issue has been identified for this product line.Capa#1998036 has been initiated, and a team has been assembled in order to investigate the issue.
|
| |
|