Model Number 10848600
Medical Device Problem Code Output Problem (3005)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/06/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Siemens is conducting a thorough investigation of the reported events.As this event is under investigation, a root cause has not yet been determined.A supplement report will be filed upon completion of the investigation.Internal id # (b)(4).
 
Event or Problem Description
It was reported to siemens that a malfunction occurred while operating the artis one system.During an interventional procedure, no x-ray was available.The procedure was continued and successfully completed on an alternate unit.We are unaware of any impact to the state of health of the patient involved.Siemens has requested additional information in order to conduct an investigation of the reported event.The reported event occurred in (b)(6).
 
Additional Manufacturer Narrative
The investigation of the reported event was performed through log analysis and returned part analysis.It was determined that the system malfunction was caused by defective power supply in generator.Further investigation on defective power supply was performed.The visual check showed visible traces of heating and slight dust deposits as a result of years of operation.The technical analysis showed an open fuse caused by electric component failure leading to short circuit.Accordingly, it is inferred that the internal component failure likely due to main disturbances such as surge and leading to the power supplier defective.The power supply component was replaced onsite and the issue was resolved.It was determined this event was caused by external factors and/or a single fault condition.There was no systematic problem was identified and thus, no further corrective action will be taken.The incident described in the adverse event was not classified as a reportable event after detailed investigation because neither serious injury, death nor an unexpected, prolonged hospitalization of the patient or any other person occurred or could be expected.The corresponding probability according to the risk analysis is in the range of inconceivable.Internal id# (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARTIS ONE
Common Device Name
IMAGE-INTENSIFIED FLUOROSCOPIC X-RAY SYSTEM
Manufacturer (Section D)
SIEMENS SHENZHEN MAGNETIC RESONANCE LTD.
gaoxin c ave.
2nd, hi-tech industrial park
shenzhen, 51805 7
CH  518057
Manufacturer (Section G)
SIEMENS SHENZHEN MAGNETIC RESONANCE LTD.
gaoxin c ave.
2nd, hi-tech industrial park
shenzhen, 51805 7
CH   518057
Manufacturer Contact
rebecca tudor
40 liberty blvd.
65-1a
malvern, PA 19355
4843234198
MDR Report Key14407622
Report Number3004754211-2022-27080
Device Sequence Number19440514
Product Code OWB
UDI-Device Identifier04056869009964
UDI-Public04056869009964
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K133580
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Company Representative
Initial Reporter Occupation Other Health Care Professional
Remedial Action Replace
Type of Report Initial,Followup
Report Date (Section B) 07/18/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number10848600
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/06/2022
Supplement Date Received by Manufacturer07/18/2022
Initial Report FDA Received Date05/16/2022
Supplement Report FDA Received Date07/18/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-