Model Number 29420
Medical Device Problem Codes Contamination (1120); Unsealed Device Packaging (1444)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/22/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Age at time of event: 18 years or older.
 
Event or Problem Description
It was reported that a device contamination occurred.A 135/20 renegade hi-flo catheter was selected for use.During preparation, it was noted that the packaging was not sealed and the sterility of the device was compromised.The procedure was completed with another of same device.No complications were reported and patient was stable post procedure.
 
Event or Problem Description
It was reported that a device contamination occurred.A 135/20 renegade hi-flo catheter was selected for use.During preparation, it was noted that the packaging was not sealed and the sterility of the device was compromised.The procedure was completed with another of same device.No complications were reported and patient was stable post procedure.
 
Additional Manufacturer Narrative
A2 - age at time of event: 18 years or older.Device evaluated by mfr: the device with its packaging has been received for analysis.The outer box seal was broken, and the inner pouch had been opened (across the top of the pouch and down halfway of the right side).Along the top of the pouch were residue signs that it had been sealed and pulled open.The device itself was in the shipping hoop and showed no signs of use.The residual of the sealing process on the pouch confirms the pouch had been sealed at one time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RENEGADE HI-FLO
Common Device Name
CATHETER, CONTINUOUS FLUSH
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORK LIMITED
model farm road
cork
EI  
Manufacturer Contact
jay johnson
4100 hamline ave n
arden hills, MN 55112
6515810888
MDR Report Key14408855
Report Number2134265-2022-05185
Device Sequence Number5564948
Product Code KRA
UDI-Device Identifier08714729280644
UDI-Public08714729280644
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K140329
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/09/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/08/2024
Device Model Number29420
Device Catalogue Number29420
Device Lot Number0027457034
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 04/24/2022
Supplement Date Received by Manufacturer07/15/2022
Initial Report FDA Received Date05/16/2022
Supplement Report FDA Received Date08/09/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/08/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-