|
H.6 investigation summary: material 221716 is manufactured by rehydrating the media components with usp purified water, and thoroughly mixing until a homogeneous solution is obtained.The tubes are filled, capped, torqued and then labeled by machine per standard operating procedure (sop).The tubes are terminally autoclaved in an air over pressure (aop) autoclave, per manufacturing instructions, using a validated cycle.Post autoclaving, tubes are packaged into final shipping configurations.The batch history record review for batch 1123397 was satisfactory and no quality notifications were generated during manufacturing and inspection.Formulation, filling, torquing, and autoclaving processes were within specifications.Qc inspection and testing was satisfactory at time of release.Direct staining techniques are not part of qc release testing for this product.As part of the release criteria for this product, the bhr is reviewed to confirm the following: the total elapsed time between end of formulation and start of the autoclave cycle was within the specified limits.All autoclave parameters conformed to the validated cycle parameters for this product.The minimum f0 for this product was met.The complaint history was reviewed, and no other complaints have been taken on this batch.Retention samples from batch 1123397 (10 tubes) were available for inspection.No evidence of contamination was observed in 10/10 retention samples.All retentions tubes had the expected appearance for this product of light to medium light yellow, trace hazy to clear.For further investigation 2 retention tubes were incubated.One tube was placed into 33-37-degree celsius incubation, and one tube was placed into 20-25-degree celsius incubation.At the end of a seven-day incubation period there was no microbial growth or change in the media clarity in 2/2 incubated retention tubes.Eight photos were received to assist with the investigation: the first photo shows the caps of eighty tubes in a tube rack.The second photo shows the media of the tubes.The media appears medium yellow clear as described in the certificate of analysis.The third photo shows tubes from batch 1123397, in a tube rack.The media appears medium yellow clear as described in the certificate of analysis.The fourth photo verifies that the tubes are from batch 1123397.The fifth photo shows the bottom of a tube.The tube has a crack.The sixth photo shows a gram stain of gram variable rods.The seventh photo also shows a gram stain of gram variable rods.The last photo also shows a gram stain of gram variable rods.Returns were received for the investigation.Sixty-six tubes from batch 1123397 were received in a shipping box.One tube was received cracked and 65 tubes were received in good condition with no evidence of contamination/turbidity.For further investigation, return tubes were incubated.Thirty-two return tubes were incubated in the 20-25 degree c incubator, and 32 return tubes was placed in the 33-37 degree c incubator.At 7 days incubation, there were no signs of growth or turbidity in 65/65 returned tubes.One tube was not incubated and used to perform gram stain.No viable organisms found the gram stain consisted of gram variable rods.Caution should be exercised in reporting direct gram stain and/or other direct microbiological stain results on tissue specimens processed with this medium due to the possible presence of nonviable organisms in the culture medium.Culture media sometimes contain dead organisms derived from medium constituents, which may be visible in smears of culture media.Other sources of dead organisms visible upon gram staining include staining reagents, immersion oil, glass slides, and the specimens used for inoculation.If there is uncertainty about the validity of the gram stain, the culture should be reincubated for another hour or two and the test repeated before a report is given.No actions are indicated at this time due to no trends observed for this defect.Bd will continue to trend complaints for contamination and non-viables.This complaint can be confirmed for non-viables.Notes: risk management review indicates the potential risk of the defect reported was assessed as severity [s2], per [baltrmterminalgpaph ], rev [02], id [2.23].
|