ZIMMER SWITZERLAND MANUFACTURER GMBH ANN, PROXIMAL HUMERUS, RIGHT, 7X160MM; ROD, FIXATION
|
Back to Search Results |
|
| Model Number |
N/A |
| Medical Device Problem Code |
Migration (4003)
|
| Health Effect - Clinical Code |
Insufficient Information (4580)
|
| Date of Event |
04/20/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Concomitant medical devices: blunt tip screw, 4x42mm; item# 47248604240; lot# 3073795.Blunt tip screw, 4x42mm; item# 47248604240; lot# 3076740.Blunt tip screw, 4x44mm; item# 47248604440;lot# 3076741.Cortical bone screw, 4x30mm; item# 47248613040, lot# 3073753.Cortical bone screw, 4x32mm; item# 47248613240, lot# 3068973.Proximal humerus nail cap, 10.5x2.5mm; item# 47248801002; lot# 3068978.Report source¿ foreign ¿ (b)(6).No product return.Product remains implanted.Multiple mdr reports were filed for this event, please see associated reports: 0009613350-2022-00283, 0009613350-2022-00284, 0009613350-2022-00286.The device will not be returned for analysis; however, an investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch 3500a will be submitted.
|
| |
|
Event or Problem Description
|
|
It was reported that one of the proximal screws backed out from the proper position one week after initial implantation.The surgeon is keeping an eye on the patient's condition.No revision surgery planned so far.No harm reported.Attempts have been made and no further information has been provided.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).This follow-up report is being submitted to relay additional information.The following sections were updated: b4, b5, g3, g6, h2, h6, h10.Review of the device history records identified no deviations or anomalies during manufacturing that could be related to the reported event.Based on the investigation it could be assumed that further possible contributing factors to the migration of the screw might be multifactorial related to either patient condition, behavior or implantation procedure.If and to what extent any of these aspects may have influenced the migration of the screw remains unknown.A deeper investigation was performed which identified the design limitation of the corelock mechanism as a potential contributing factor as well.However, further biomechanical testing was carried out and as the product performance is in an acceptable range in comparison with legally marketed similar devices, no design changes were conducted.In conclusion, as the cause may be multifactorial an exact root cause could not be identified for the migration of the screw.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further event information available at the time of this report.
|
| |
|