It was reported that, after left bhr-tha was performed on (b)(6) 2009 due to hip arthrosis, the patient experienced elevated metal ion levels, esr and crp.Ultrasound showed fluid collection on left hip.This adverse event was treated with revision surgery on (b)(6) 2014.Patient's current health status is unknown.
|
|
H3, h6: it was reported that left hip revision surgery was performed.As of today, the implanted devices, all of which were used in treatment have not been returned for evaluation.Without definitive lot numbers a complete complaint history review cannot be performed for the devices involved in the incident.A review of the historical complaints data was performed using part numbers and the reported failure modes to evaluate patterns of repeated failures or defects in a timeframe prior 12 months as of the complaint aware/reopen date.Other similar complaints have been identified for the part number and the reported failure mode.This failure will continue to be monitored.As no device batch numbers were provided for investigation for the acetabular cup and the hemi head, manufacturing record review, device labelling / ifu review could not be performed.If more information is received, this investigation will be reopened.A risk management review was performed.The alleged failure modes and associated risks have been anticipated within the risk file and the anticipated risk level is still adequate.A review of historic escalation actions related to the products and similar complaint events was performed.Following the review, prior applicable escalation actions were identified and confirmed to reduce associated risks as far as possible.No further escalation actions required.The available medical documents were reviewed.The clinical information provided, of elevated metal ions, cloudy fluid, pseudotumor, necrosis and corrosion at the femoral head/ neck junction may be consistent with a reaction to metal debris.However, the source and the root cause cannot be determined with the available documentation.It cannot be concluded that the reported clinical findings are associated with the implant failure.The patient impact beyond the revision and expected transient post-op convalescence period cannot be determined.Based on the available information we can confirm the reported complaint, however without further information our investigation remains inconclusive, and a definitive root cause cannot be determined.Specific factors known to contribute to the alleged fault are excessive physical activity levels, unreasonable stress on replacement system, excessive patient weight, trauma to the joint replacement, loosening of components may increase production of wear particles and accelerate damage to the bone.Should the devices or additional information be received, the complaint will be reopened.Based on this investigation, the need for corrective and preventative actions is not indicated.
|