CORDIS CORPORATION OPTEASE RETR FILTER 55 FEMORAL; FILTER, INTRAVASCULAR, CARDIOVASCULAR
|
Back to Search Results |
|
| Model Number |
466FXXXX |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Internal Organ Perforation (1987); Perforation (2001); Perforation of Vessels (2135)
|
| Date of Event |
02/21/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
It was reported that a patient underwent placement of an optease vena cava filter.The information provided indicated that the filter subsequently malfunctioned and caused perforation abutting adjacent organs.The indication for the filter implant, procedural details and medical history of the patient have not been provided and there is currently no additional information available for review.The product was not returned for analysis and the sterile lot number has not been provided; therefore, no device analysis nor device history record review could be performed.The optease vena cava filter is indicated for use in the prevention of recurrent pulmonary embolism (pe) via percutaneous placement in the vena cava for patients in which anticoagulants are contraindicated, anticoagulant therapy for thromboembolic disease has failed, emergency treatment following massive pe where anticipated benefits of conventional therapy are reduced or for chronic, recurrent pe where anticoagulant therapy has failed, or is contraindicated.The purpose of a vena cava filter is to catch thrombus from the lower extremities as it travels along normal blood flow patterns up towards the heart.Vessel perforation is a known adverse event associated with implanting vena cava filters and is listed as such in the instructions for use (ifu).The ifu notes vessel damage such as intimal tears and perforation as procedural and long-term complications related to ivc filters.Without images available for review the reported events could not be confirmed or further clarified.Given the limited information available for review at this time, there is nothing to suggest that the reported events are related to the design and manufacturing process of the device; therefore, no corrective action will be taken.Should additional information become available, the file will be updated accordingly.
|
| |
|
Event or Problem Description
|
|
As reported by the legal department, the patient underwent placement of the optease vena cava filter.The filter subsequently malfunctioned and caused injury and damages to the patient including, but not limited to, perforation abutting adjacent organs.As a direct and proximate result, the patient suffered life-threatening injuries and damages and required extensive medical care and treatment.As a further proximate result, the patient has suffered and will continue to suffer significant medical expenses, pain and suffering, and other damages.
|
| |
|
Additional Manufacturer Narrative
|
|
It was reported that a patient underwent placement of an optease vena cava filter.The information provided indicated that the filter subsequently malfunctioned and caused perforation abutting adjacent organs.The patient reported becoming aware of perforation of the inferior vena cava (ivc) and perforation of abutting adjacent organ, approximately fourteen years and four months post implant.The patient also reported anxiety related to the filter.According to the medical record the patient had a significant pelvic fracture and a bowel resection with colostomy due to significant intraabdominal trauma.The ivc filter placement was planned due to the extent of the injuries and immobility, as well as a risk for deep vein thrombosis (dvt) and pulmonary embolism in the setting of inability to effectively use anticoagulation.Following fixation of a right arm fracture, the ivc filter was implanted while the patient was still under anesthesia.The filter was placed via the right common femoral vein and deployed at the level of the l2-l3 lumbar vertebrae, below the renal veins.A follow up venogram confirmed excellent positioning of the ivc filter with excellent wall apposition of the filter graft below the renal veins.The patient tolerated the procedure well and there were no complications reported.The product was not returned for analysis and the sterile lot number has not been provided; therefore, no device analysis nor device history record review could be performed.The optease vena cava filter is indicated for use in the prevention of recurrent pulmonary embolism (pe) via percutaneous placement in the vena cava for patients in which anticoagulants are contraindicated, anticoagulant therapy for thromboembolic disease has failed, emergency treatment following massive pe where anticipated benefits of conventional therapy are reduced or for chronic, recurrent pe where anticoagulant therapy has failed, or is contraindicated.The purpose of a vena cava filter is to catch thrombus from the lower extremities as it travels along normal blood flow patterns up towards the heart.Vessel perforation is a known adverse event associated with implanting vena cava filters and is listed as such in the instructions for use (ifu).The ifu notes vessel damage such as intimal tears and perforation as procedural and long-term complications related to ivc filters.Without images available for review the reported events could not be confirmed or further clarified.Anxiety does not represent a device malfunction and may be related to underlying patient specific issues.Given the limited information available for review at this time, there is nothing to suggest that the reported events are related to the design and manufacturing process of the device; therefore, no corrective action will be taken.Should additional information become available, the file will be updated accordingly.
|
| |
|
Event or Problem Description
|
|
The following additional information received per the patient¿s implant records indicate that the patient had a significant pelvic fracture and had a bowel resection with colostomy due to significant intraabdominal trauma.Inferior vena cava (ivc) filter placement was planned due to the extent of the patient¿s injuries and immobility, as well as a risk for deep vein thrombosis (dvt) and pulmonary embolism in the setting of inability to effectively use anticoagulation.The patient was brought to the operating room for fixation of a right arm fracture.Following the surgery, while the patient was still under general anesthesia, an ivc filter implantation was performed.Intravenous (iv) antibiotics were given, and venous access was obtained via the right common femoral vein.The patient had a pelvic fixator in place, but it was verified that there was adequate room to obtain the venous access.The patient also had pelvic lacerations which were irrigated the day prior to the surgery and were packed.The pelvic lacerations were able to be negotiated to provide access for right femoral vein cannulation.Both of the patient¿s groins, as well as their lower pelvis were sterilely prepared and draped.An unknown introducer needle was used to cannulate the common femoral vein under fluoroscopic guidance.An unknown j-tip guidewire was inserted into the common femoral vein and advanced into the ivc, and an unknown 5f catheter sheath introducer (csi) was placed in the common femoral vein.An angiogram of the right iliac vein was performed to confirm that not clots were present in the iliac
system.An unknown 5f pigtail catheter was then placed in the ivc to perform an angiogram of the ivc.The ivc angiogram was performed to confirm there were no caval clots, as well as confirm the position of the renal veins.The renal veins were seen at the first lumbar (l1) vertebral body level.An unknown guidewire was then inserted to remove the unknown 5f csi, and a 6f optease retrievable filter csi was inserted.This was followed by the deployment and placement of the ivc filter at the level of the l2 (second lumbar vertebrae) ¿ l3 (third lumbar vertebrae) below the renal veins.A follow up venogram was performed which confirmed excellent positioning of the ivc filter with excellent wall apposition of the filter graft below the renal veins.The unknown 5f csi was removed and manual pressure was held for 15 minutes to achieve hemostasis.There was no evidence of hematoma at the access site, and a dry sterile dressing was placed.The patient tolerated the procedure well and there were no complications reported.Additional information received in the patient profile form (ppf) states that the patient experienced perforation of the ivc, perforation of abutting adjacent organ.The patient became aware of the reported event approximately fourteen years and four months after the index procedure.The patient continues to experience anxiety related to the filter.
|
| |
|