Model Number 75007309
Medical Device Problem Code Fracture (1260)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/26/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Internal complaint reference: case (b)(4).
 
Event or Problem Description
It was reported that a sl-plus/sbg/ipa mia offset adapter 10mm was found to be broken.As this was noticed upon field inspection, there was not patient involvement.
 
Additional Manufacturer Narrative
H3, h6: it was reported that a sl-plus/sbg/ipa mia offset adapter 10mm was found to be broken.A visual inspection of the returned device confirmed the stated failure mode.The release lever is fractured on the opposing side to the actuating area of the lever.The fragment was not returned for investigation.Apart from the fracture, the instrument shows signs of wear as it can be expected after repeated use over time.A review of the complaint history of the affected device was performed.No additional complaint for the batch in question was detected.For the device 75007309, one additional complaint with a comparable failure mode was reported in 2010.A review of the production documentation did not detect any deviation that could have contributed to the reported failure mode.The part was manufactured in 2008.The function of the complaint instrument in combination with a rasp was tested by using the respective test gauge.No deviation was detected.Hence, the functionality of the instrument is maintained despite the damage.A review of the risk management documentation verifies the failure mode and severity of the reported issue.The release lever of the device is designed as a spring which is therefore subjected to repeated compressive forces when connecting and disconnecting the device with a broach.Previous investigations revealed that under specific circumstances, this release lever of the device may fracture during compression.The root cause is attributed to a design issue.A new design of the device has been released in order to reduce the reoccurrence of this issue.This version of the device will be monitored for similar issues.The performance of the device is nonetheless within the risks, which are anticipated in the risk management documentation of the product.No further escalation is required.Please note that according to document "processing (cleaning, disinfection and sterilization) of instruments from smith & nephew orthopaedics ag" (lit.N°03389-en 1363 v3 11/19), all devices must be inspected and controlled for proper functioning after cleaning/disinfection.This version of the device will be monitored for similar issues.The returned device will be discarded.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SL-PLUS/SBG/IPA MIA OFFSET ADAPTER 10MM
Common Device Name
PROSTHESIS, HIP, HEMI-, FEMORAL, METAL/POLYMER, CEMENTED OR UNCEMENTED
Manufacturer (Section D)
SMITH & NEPHEW ORTHOPAEDICS AG
schachenallee 29
aarau CH-50 00
SZ  CH-5000
Manufacturer (Section G)
SMITH & NEPHEW ORTHOPAEDICS AG
schachenallee 29
aarau CH-50 00
SZ   CH-5000
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key14462433
Report Number9613369-2022-00261
Device Sequence Number4482709
Product Code KWY
UDI-Device Identifier07611996076394
UDI-Public07611996076394
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K123598
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/28/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number75007309
Device Catalogue Number75007309
Device Lot NumberE59831
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/26/2022
Supplement Date Received by Manufacturer06/24/2022
Initial Report FDA Received Date05/20/2022
Supplement Report FDA Received Date06/28/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-