Model Number 702753
Medical Device Problem Codes Break (1069); Fracture (1260)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/02/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Once the investigation has been completed any additional information will be reported in a supplemental report.
 
Event or Problem Description
It was reported that during a planned axsos plt extraction, the screw was extracted slightly by hand and then attempted to be extracted with an electric drill, but it was forwarded, causing the locking screw stuck to the plate.The subsequent attempt to remove it was too hard and the tips of two screwdrivers were broken.A t10 screwdriver prepared for other cases was used to remove, but also was broken.After that, extraction was completed using a carbide drill and crown drill.All debris was removed from the patient.
 
Additional Manufacturer Narrative
The reported event could be confirmed, since the product was returned for evaluation and matches the alleged failure mode.The device inspection revealed the following: the device was received with a broken tip at the distal end.Only one part of the broken screwdriver is available for inspection.Microscopic views of the fracture surface show rotational deformation indicating forward application of high torsional load.The overall breakage pattern reveals brittle fracture most likely due to a combination of high torsional and bending load.Furthermore, a hardness test according to rockwell on the returned item indicates the material being in accordance to the values in the material specification.A review of the device history for the reported lot did not indicate any abnormalities.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.No indications of material, manufacturing, or design related problems were found during the investigation.Based on the investigation, the root cause was finally attributed to a user-related issue.The failure was caused by applying too much torsional and bending force which did lead to a mechanical overload during the extraction of a screw.If any further information is provided, the complaint report will be updated.
 
Event or Problem Description
It was reported that during a planned axsos plt extraction, the screw was extracted slightly by hand and then attempted to be extracted with an electric drill, but it was forwarded, causing the locking screw stuck to the plate.The subsequent attempt to remove it was too hard and the tips of two screwdrivers were broken.A t10 screwdriver prepared for other cases was used to remove, but also was broken.After that, extraction was completed using a carbide drill and crown drill.All debris was removed from the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SCREWDRIVER BIT AXSOS T15, AO FITTING 4.0MM LOCKING SET
Common Device Name
ORTHOPEDIC MANUAL SURGICAL INSTRUMENT
Manufacturer (Section D)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
SZ  2545
Manufacturer (Section G)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
SZ   2545
Manufacturer Contact
anna jusinski
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key14477105
Report Number0008031020-2022-00266
Device Sequence Number17476864
Product Code LXH
UDI-Device Identifier07613327005028
UDI-Public07613327005028
Combination Product (Y/N)N
Initial Reporter CountryJA
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/05/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number702753
Device Catalogue Number702753
Device Lot NumberJ03675
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 05/02/2022
Supplement Date Received by Manufacturer07/12/2022
Initial Report FDA Received Date05/23/2022
Supplement Report FDA Received Date08/05/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/25/2016
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-