Model Number BXA067902A
Medical Device Problem Code Obstruction of Flow (2423)
Health Effect - Clinical Code Obstruction/Occlusion (2422)
Date of Event 04/19/2021
Type of Reportable Event Serious Injury
Event or Problem Description
On (b)(6) 2020 the patient underwent endovascular treatment of a thoracoabdominal aortic aneurysm using gore® excluder® thoracoabdominal branch endoprostheses (tambe) in the aaa1701 tambe pivotal study.On (b)(6) 2021 occlusion was observed in the gore® viabahn® vbx balloon expandable endoprosthesis used as a bridging stent in the patient's right renal artery.It was reported that the occlusion was suspected to be related to the sharp angle that the device takes as it bridges from the tambe device.Reportedly the patient had a decline in renal function but does not require hemodialysis.It was reported that the event is ongoing.No treatment has been performed or is planned for the future.There were no further reported issues and there were no reported issues with any other implanted devices.
 
Additional Manufacturer Narrative
Cbas® heparin surface incorporates cbas-heparin manufactured from heparin sodium api, which is covalently bound to the device surface and is essentially non-eluting.Due to no device return, an investigation could not be performed.A review of the manufacturing records indicated the lot met pre-release manufacturing specifications.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® VIABAHN® VBX BALLOON EXPANDABLE ENDOPROSTHESIS
Common Device Name
ILIAC COVERED STENT, ARTERIAL
Manufacturer (Section D)
W. L. GORE & ASSOCIATES, INC.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
MEDICAL ECHO RIDGE B/P
3250 w. kiltie lane
flagstaff AZ 86005
Manufacturer Contact
spencer deboard
1505 n. fourth street
flagstaff, AZ 86004
9285263030
MDR Report Key14477887
Report Number2017233-2022-02956
Device Sequence Number4680323
Product Code PRL
UDI-Device Identifier00733132637492
UDI-Public00733132637492
Combination Product (Y/N)Y
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
P160021
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Reporter Type Manufacturer
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 05/23/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date03/05/2023
Device Model NumberBXA067902A
Device Catalogue NumberBXA067902A
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/29/2022
Initial Report FDA Received Date05/23/2022
Date Device Manufactured03/06/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Life Threatening; Hospitalization;
Patient Age71 YR
Patient SexMale
Patient Weight106 KG
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-