|
Product complaint # (b)(4).The purpose of this mdr submission is to report the findings of the device investigation.The embolic coil was stretched, meeting regulatory reporting criteria.Information regarding patient weight, height, medical history, race, and ethnicity was not reported.Procode: krd/hcg.Initial reporter: the customer contact information, including name, occupation, phone, fax, and e-mail address, was not reported.Missing information from this report is identified as blank; this information was not provided in the reported event or available at the time of report submission.A supplemental report will be submitted if new facts arise which materially alter information submitted in a previous mdr report.This report is being submitted pursuant to the provisions of 21 cfr, part 4.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by cerenovus, or its employees that the report constitutes an admission that the product, cerenovus, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Complaint conclusion: as reported by the field, during a coil embolization, a 2.5x3.5 orbit galaxy xtrasoft coil (640cx2535, 30641872) was being used as the first coil.The physician decided to pull it out for re-deployment after trying another size of coil first.During resheathing the coil, the introducer failed to be re-zipped.The physician decided to pull it out because the coil's size was not appropriate with aneurysm.The physician used a same like product.The procedure was successfully finished and there was no patient injury reported.A non-sterile og cmplx xtrasoft coil 2.5x3.5 was received for analysis on a pouch.The device was visually inspected, and it was found that the hypo-tube is severely kinked, also, it was noted that the introducer has a split condition, causing the hypo-tube component to protrude.No other damages or anomalies were observed during the visual inspection.The og cmplx xtrasoft coil 2.5x3.5 was inspected under a microscope magnification, and it was found that the coil component has a stretched condition.No other damages or anomalies were observed on the device.The functional test could not be performed due to the conditions noted on the device.A manufacturing record evaluation (mre) was performed for the finished device 30641872 number, and no non-conformances related to the malfunction were identified.Upon arrival of the device, the hypo-tube of the og cmplx xtrasoft coil 2.5x3.5 was noted to be severely kinked, also, it was noted that the introducer has a split condition, causing the hypo-tube component to protrude.No other damages or anomalies were observed on the device during the visual inspection.The coil component was inspected under microscopic magnification, and it was noted to be stretched.The conditions described above precluded proper testing.However, such damages seem to be secondary to the zipping difficulty condition reported and may relate to factors not described in this complaint (e.G., excessive force applied to the device).Coil stretching is a known potential issue associated with the use of this device.The instructions for use (ifu) provides proper handling instructions for the device to prevent such issue from occurring.Stretch can occur during procedure handling where force may have been inadvertently applied.The complaint documented that there was an issue to re-zip the device; the complaint coil was removed from the patient.It is possible that force may have inadvertently been applied during the coil removal from the patient which resulted in the coil stretched.The customer complaint was confirmed, however, there is no indication that the issue reported in the complaint is a result of a defect inherently related to the device.With the limited information available, an assignment of a root cause is not possible, and no further evaluation could be conducted.A manufacturing record evaluation was performed, and no non-conformances related to the reported complaint condition were identified.It should be noted that product failure could be caused by multiple factors.The instructions for use (ifu) does contain the following recommendations: ¿ never advance, withdraw, or torque the delivery tube against resistance without first determining the cause of resistance under fluoroscopy.Manipulation of the delivery tube against resistance can cause damage and/or premature detachment of the coil.¿ if unusual friction is noted within the infusion catheter, remove the detachable coil system.¿ if friction is noted with any subsequent detachable coil system, carefully examine the detachable coil system and the infusion catheter for possible damage.Replace both if necessary.Multiple attempts to obtain additional information were unsuccessful.If information is provided at a later date, the file will be reopened and processed accordingly.As part of the cerenovus quality process, all devices are manufactured, inspected, and released to approved specifications.As part of the post market surveillance program, information from this complaint is trended to identify statistical signals for consideration of further correction action.Since there was no evidence to suggest the event was related to a manufacturing or design issue, no corrective actions will be taken at this time.
|