• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: OMNILIFE SCIENCE APEX KNEE SYSTEM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

OMNILIFE SCIENCE APEX KNEE SYSTEM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL Back to Search Results
Model Number KP-22211
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 05/18/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The complainant made no indication of any omnilife science device malfunction or deficiency related to the identity, quality, durability, reliability, safety, effectiveness or device performance contributing to the adverse event.Review of the manufacturing documentation and sterilization documentation for the devices in question revealed no deviation from process or non-conformity of product that would have caused or contributed to the adverse event.
 
Event or Problem Description
A complaint was initiated for a patient who underwent a knee revision surgery on (b)(6) 2022.The original surgery date is (b)(6) 2020.The reason for revision is reported instability.During the revision, the original tibial insert and retaining bolt were removed and replaced with new implants.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
APEX KNEE SYSTEM
Common Device Name
PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL
Manufacturer (Section D)
OMNILIFE SCIENCE
480 paramount drive
raynham MA 02767
Manufacturer (Section G)
OMNILIFE SCIENCE
480 paramount drive
raynham MA 02767
Manufacturer Contact
jamie demedeiros
480 paramount drive
raynham, MA 02767
5088226030
MDR Report Key14501133
Report Number1226188-2022-00022
Device Sequence Number20245332
Product Code JWH
UDI-Device Identifier00841690113508
UDI-Public00841690113508
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K102578
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Device Explanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 05/25/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date01/31/2022
Device Model NumberKP-22211
Device Catalogue NumberKP-22211
Device Lot Number25812
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 05/19/2022
Initial Report FDA Received Date05/25/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured01/31/2017
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient Age72 YR
Patient SexFemale
-
-