Model Number AM3014
Medical Device Problem Codes Disconnection (1171); Fluid/Blood Leak (1250)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/24/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
No product samples, videos, or photographs were provided for investigation.The lot history was reviewed and there were no relevant non-conformances found that would have contributed to the reported complaint.A probable cause cannot be identified based on the information that has been provided.
 
Event or Problem Description
The event occurred on an unknown date involving a 26" ext set w/3-port nanoclave® manifold, check valve, 2 microclave® clear, clamp, luer lock where it was reported that the rn noted the patient¿s blood pressure decreased significantly while she was assisting another patient.Upon arrival at the bedside, the manifold piece had disconnected from the manifold, causing the vasopressor to subsequently into the floor instead of the patient.The patient complained of unwell feeling due to a significant drop in blood pressure due to unintended interruption of medication.There was a patient involvement but no report of patient harm.
 
Additional Manufacturer Narrative
Received one new list #am3014, 26" ext set w/3-port nanoclave® manifold, check valve, 2 microclave® clear, clamp, luer lock; lot #5162807 and was functionally tested for bond security and though the distal port technically met specification it was well below the functional capability of the other two ports suggesting that something was different with that distal port.Visual examination reveled that the distal port was only partially ultrasonically welded around the perimeter resulting in a lower than expected (and much lower than the adjacent ports) weld.The complaint is confirmed with a probable cause of insufficient ultrasonic weld during nanoclave assembly.The device history report (dhr) was reviewed and there were no relevant non-conformances found that would have contributed to the reported complaint.Additional information: d9 - date returned to mfg initial is 7/14/2022, and f2 - uf/importer report # is (b)(4).
 
Event or Problem Description
Update: a medwatch report was received on 20-jul-2022.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
26" EXT SET W/3-PORT NANOCLAVE® MANIFOLD, CHECK VALVE, 2 MICROCLAVE® CLEAR, CLAM
Common Device Name
STOPCOCK, I.V. SET
Manufacturer (Section D)
ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V.
avenida cuarzo no. 250
ensenada, b.cfa. 22790
MX  22790
Manufacturer Contact
michael visocnik
600 n. field dr.
lake forest, IL 60045
2247062300
MDR Report Key14518589
Report Number9617594-2022-00143
Device Sequence Number14854221
Product Code FMG
UDI-Device Identifier00887709086227
UDI-Public(01)00887709086227(17)260101(10)5162807
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
K964435
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/11/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/01/2026
Device Model NumberAM3014
Device Catalogue NumberAM3014
Device Lot Number5162807
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/11/2022
Supplement Date Received by Manufacturer07/20/2022
Initial Report FDA Received Date05/26/2022
Supplement Report FDA Received Date08/17/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/01/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
VASOPRESSSOR, MFR UNK
Patient Age62 YR
Patient SexFemale
-
-