• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: K2M, INC. DEFORMITY, UNIPLANAR SCREW; SIZE Ø6.5X45 MM; THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

K2M, INC. DEFORMITY, UNIPLANAR SCREW; SIZE Ø6.5X45 MM; THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM Back to Search Results
Model Number 801-36545M
Medical Device Problem Code Migration (4003)
Health Effect - Clinical Codes Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/04/2022
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Status and location of the device is unknown.
 
Event or Problem Description
It was reported that a mesa uniplanar screw slipped axially post-operatively.Revision surgery has not been scheduled nor performed at this time.
 
Additional Manufacturer Narrative
Device analysis could not be performed as the device was not returned.Device history records could not be reviewed as a valid lot number was not provided and could not be obtained.Complaint history records were reviewed for this catalog number; similar complaints were identified.Although the devices remains implanted and can therefore not be analyzed, x-ray imaging was provided by the field.Construct migration cannot be confirmed in the provided imaging.Similar construct design x-rays from the same surgeon for the same failure mode were reviewed by a consultant spine health care provider.The physician believes that the construct design with difficult deformities was the most likely contributing factor to the event.The operating surgeon used a low density screw construct which ended on the convex curve of the spinal deformity.The low screw density and short length of construct, along with possible loss of correction, may not have been enough to counter the force of the spine trying to revert to its original position.This may result in eventual failure at the distal most screw (where biomechanical loading is most likely greater) leading to the rod slipping from the screw.Additionally, the construct was implanted in 2019 and has been in place for over three years.From the ifu: "internal fixation devices are load sharing devices which maintain alignment until healing occurs.If healing is delayed or does not occur the implant could eventually break, bend or loosen.Loads produced by load bearing and activity levels will impact the longevity of the implant." h3 other text : device location is unknown.
 
Event or Problem Description
It was reported that a mesa uniplanar screw slipped axially post-operatively.Revision surgery was planned.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DEFORMITY, UNIPLANAR SCREW; SIZE Ø6.5X45 MM
Common Device Name
THORACOLUMBOSACRAL PEDICLE SCREW SYSTEM
Manufacturer (Section D)
K2M, INC.
600 hope parkway se
leesburg VA 20175
Manufacturer (Section G)
K2M, INC.
600 hope parkway se
leesburg VA 20175
Manufacturer Contact
rita karan
2 pearl court
allendale, NJ 07401
2017608000
MDR Report Key14524956
Report Number3004774118-2022-00216
Device Sequence Number12137969
Product Code NKB
UDI-Device Identifier10888857140301
UDI-Public10888857140301
Combination Product (Y/N)N
Initial Reporter CountryNL
PMA/510(K) Number
K141873
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2019
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/09/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number801-36545M
Device Catalogue Number801-36545M
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 05/17/2022
Supplement Date Received by Manufacturer08/12/2022
Initial Report FDA Received Date05/27/2022
Supplement Report FDA Received Date09/09/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-