• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: WILLIAM COOK EUROPE ZENITH® TX2 DISSECTION ENDOVASCULAR GRAFT TAPERED COMPONENT; MIH SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

WILLIAM COOK EUROPE ZENITH® TX2 DISSECTION ENDOVASCULAR GRAFT TAPERED COMPONENT; MIH SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT Back to Search Results
Model Number G47485
Medical Device Problem Codes Failure to Advance (2524); Difficult to Advance (2920)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/19/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Manufacturer ref# (b)(4).Pma/510k: p180001.Investigation is still in progress.
 
Event or Problem Description
Description of event according to initial reporter: device would not pass through the right common iliac artery.A little bit of calcification and tortuosity.A different cook device was used.Patient outcome: the complainant did not experience any adverse effects due to this occurrence.
 
Additional Manufacturer Narrative
Manufacturer ref# (b)(4).After investigation the event for this pr# is no longer reportable.Summary of investigational findings: a 74-year-old male underwent a surgery, where a zdeg-pt-40-32-165-pf-us (complaint device) was to be implanted.The patient´s anatomy was reported to have a little bit of calcification, tortuosity and narrowing at the internal iliac and common iliac.Physician states that this didn¿t appear on ct.It was reported that the device would not pass through the right common iliac artery.A different cook device was used, and the procedure was completed.The patient did not experience any adverse effects.No device was returned, and no images were received.Review of the device history record gave no indication of the device being produced out of specification.Based on the provided information tortuous anatomy, calcification and narrowing in the internal iliac and common iliac might have contributed to the advancement inability.Cook will reopen the complaint if further information is received.Cook medical will continue to monitor for similar events.This report is required by the fda under 21 cfr part 803.This report is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement made in it is intended to be an admission that any cook device is defective or malfunctioned; that a death or serious injury occurred; or that any cook device caused or contributed to; or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Event or Problem Description
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ZENITH® TX2 DISSECTION ENDOVASCULAR GRAFT TAPERED COMPONENT
Common Device Name
MIH SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
Manufacturer (Section D)
WILLIAM COOK EUROPE
sandet 6
bjaeverskov 4632
DA  4632
Manufacturer (Section G)
WILLIAM COOK EUROPE
sandet 6, dk-4632
bjaeverskov
Manufacturer Contact
lissi walmann
sandet 6, dk-4632
bjaeverskov 
MDR Report Key14546072
Report Number3002808486-2022-00752
Device Sequence Number6774090
Product Code MIH
UDI-Device Identifier10827002474854
UDI-Public(01)10827002474854(17)250309(10)E4230857
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 07/21/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/09/2025
Device Model NumberG47485
Device Catalogue NumberZDEG-PT-40-32-165-PF-US
Device Lot NumberE4230857
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 05/19/2022
Supplement Date Received by Manufacturer07/20/2022
Initial Report FDA Received Date05/31/2022
Supplement Report FDA Received Date07/20/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured03/09/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age74 YR
Patient SexMale
-
-