Model Number IMPL SYS,CMC MINI T-ROPE,1.1 MM
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/02/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The contribution of the device to the reported event could not be determined as the device was not returned for evaluation.The root cause of the event could not be determined from the information available and without device evaluation.If the device becomes available for evaluation, a follow-up report will be submitted.
 
Event or Problem Description
On (b)(6) 2022, it was reported by a distributor via email that an ar-8919ds cmc mini tightrope nitinol loop broke off in the k-wire within the first metacarpal tunnel.The loop was retrieved and removed from inside patient, another cmc mini tightrope was opened.The loop broke again in the tunnel, just like the previous one; however, this remain partially intact with the wire and did not need to be removed.This was discovered during a thumb mcm suspensionplasty procedure on (b)(6) 2022 but was completed as an lrti procedure instead.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IMPL SYS,CMC MINI T-ROPE,1.1 MM
Common Device Name
WASHER, BOLT NUT
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
vik bajnath
8009337001
MDR Report Key14546916
Report Number1220246-2022-04970
Device Sequence Number17411719
Product Code HTN
UDI-Device Identifier00888867048966
UDI-Public00888867048966
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K140328
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Distributor
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial
Report Date (Section B) 05/31/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberIMPL SYS,CMC MINI T-ROPE,1.1 MM
Device Catalogue NumberAR-8919DS
Device Lot Number14913292
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/09/2022
Initial Report FDA Received Date05/31/2022
Date Device Manufactured01/11/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-