| Model Number |
142122-07 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Restenosis (4576)
|
| Date of Event |
04/30/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
This mdr is related to 3011632150-2022-00027.There was no reported device malfunction and the device was not returned for analysis.A review has been performed of the manufacturing certificate of conformance associated with this lot.There were no non-conformances or deviations which could be associated with this event.Based on the case information and related record review, a conclusive cause for the reported patient effects, and the relationship to the product, if any, cannot be determined.The reported patient effect of restenosis is listed in the biomimics 3d instructions for use and are known patient effects of peripheral stenting procedures.There is no indication of a product quality issue with respect to the design, manufacture or labelling of the device.If further information regarding this event becomes available, a follow-up report will be submitted.
|
| |
|
Event or Problem Description
|
|
This mdr is related to 3011632150-2022-00027.The patient was treated as part of the mimics 3d usa post-market observational study on (b)(6) 2021.The subject was implanted with two biomimics-3d stents (a 7.0 x 60mm and a 7.0 x 80mm) to treat a denovo lesion of the sfa middle third to distal third artery in the left leg.A contralateral approach was used and pre-dilatation and post-dilatation of the target lesion was conducted with percutaneous transluminal angioplasty.Atherectomy was also performed pre stent placement.On the 30-april, an event of restenosis of treated segment (target lesion) was reported from the site.It was reported as "not related" to the device or procedure but to worsening pre-existing condition.It was also reported as target lesion related.The patient outcome is reported as "resolved/recovered." the device remains implanted.On review of the event at safety monitoring review (smr) by veryan, it was determined to be possibly related to the device.
|
| |
|
Additional Manufacturer Narrative
|
|
Date of report corrected from 04 june 2022 to 01 june 2022.
|
| |
|
Additional Manufacturer Narrative
|
|
This mdr is related to 3011632150-2022-00027.This event of restenosis was subsequently removed from the study database by the clinical site and this supplemental report is updating the information provided on the initial report.
|
| |
|
Event or Problem Description
|
|
This mdr is related to 3011632150-2022-00027.The patient was treated as part of the mimics 3d usa post-market observational study on (b)(6) 2021.The subject was implanted with two biomimics-3d stents (bm3d) (a 7.0 x 60mm and a 7.0 x 80mm - the subject of this report ) to treat a denovo lesion of the superficial femoral artery (sfa) middle third to distal third artery in the left leg.A contralateral approach was used and pre-dilatation and post-dilatation of the target lesion was conducted with percutaneous transluminal angioplasty (pta).Atherectomy was also performed pre stent placement.On the 30-april-22, an event of restenosis of treated segment (target lesion) was reported from the site.This event of restenosis was subsequently removed from the study database by the clinical site.It was reviewed by veryan on 28-nov-22 and as a result of the removal of the event by the site, this mdr supplemental is updating the information provided on the initial report.
|
| |
|