• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON, DICKINSON & CO. (SPARKS) BD BACTEC¿ FX, INSTRUMENT BOTTOM, PACKAGED; SYSTEM, BLOOD CULTURING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON, DICKINSON & CO. (SPARKS) BD BACTEC¿ FX, INSTRUMENT BOTTOM, PACKAGED; SYSTEM, BLOOD CULTURING Back to Search Results
Model Number 441386
Medical Device Problem Code False Positive Result (1227)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/05/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Medical device expiration date: na.A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that false positive results were obtained using the bd bactec¿ fx, instrument bottom, packaged after rack replacement.There was no report of patient impact.The following information was provided by the initial reporter: it was reported by the customer that the instrument had displayed false positives shortly after rack replacement.
 
Additional Manufacturer Narrative
H.6.Investigation summary: a complaint of "false positive results" was received against instrument bottom bactec fx, material no: 441386, serial no: (b)(6).Logs files were reviewed and no instrument issues were identified.The complaint is not confirmed.The root cause is unknown.Review of device history record for instrument serial number: (b)(6) is not required because this complaint does not allege an early life failure or failure at installation and has changed configuration since release from manufacturing due to service repairs/pms.Device was installed on (b)(6) 2020.Samples were not received by quality for investigation and thus, returned material investigation could not occur.Service history review revealed 1 previous complaints for this issue.Complaints for ¿results¿ issues which included " false positives " complaints are under statistical control for the month of may 2022.The upper control limit was not breached.Quality will continue to monitor the " false positives ¿complaints.No trends were identified.Per baltrmbactecinstraph revision 15, the error related to this complaint is considered user inconvenience, which is an s1; reference row id 1.2c.No new risks or hazards were identified.
 
Event or Problem Description
(b)(6): 2022-05-11 22:10:53 (gmt).Reviewed, all info present.(b)(6) : 2022-05-09 20:03:43 (gmt).Log review complete: there is no instrument related issue that would have caused the false positives.During the rack repair for case: (b)(4) we had to reboot the instrument a few times within a 40 minute time span which unfortunately likely caused the false positives.The instrument is performing within specifications and you can continue to use it.Notified customer, this case can be closed.(b)(6): 2022-05-06 14:37:20 (gmt).Reviewed, pending additional information.It was reported by the customer that the instrument had displayed false positives shortly after rack replacement on (b)(6).(b)(6): 2022-05-05 19:40:59 (gmt).Correction - please omit the following serial numbers.They were not associated with the fps.(b)(6).(b)(6) : 2022-05-05 19:40:40 (gmt).Please review the below information pertaining to the false positives: when did you start using plastic bottles? customer has stated always using the plastic bottles and ped bottles were converted about two years ago.Have you noticed a difference in sensor color or anything else unusual on fp bottles? no, customer is stating there are some air bubbles on a few of the bottles, but for the most part look normal.Have you noticed any issue with the cap seal or septum on fp bottles? customer confirms they all seem to look normal how are your bottles stored prior to use? protected from light? stored in the phlebotomy's store room but customer cannot confirm for sure since they don't keep them in the lab.What is the time delay between collection and entry into an instrument? customer estimates about a 2 hour delay before vials are entered into the instrument since they are coming from different locations.Are bottles cold upon loading into instrument (colder than normal room)? no.What were wbc counts for bottles? customer did not perform.Were the bottles overfilled? no.Are there any lab accession labels on the bottom of the bottle? no.(b)(6): 2022-05-05 19:40:21 (gmt).Please review the below information pertaining to the false positives: instrument: serial#s of instruments with fp bottles: (b)(6).Software version in use: 6.40a.Are the fp all in same instrument? fps have originated from stack 1: 3 fps - drawer b , 3 from stack 1 - drawer a , 8 from stack 2 - drawer c, 1 fp - stack 2 drawer a rack? fps have originated from stack 1: 3 fps - drawer b , 3 from stack 1 - drawer a , 8 from stack 2 - drawer c, 1 fp - stack 2 drawer a drawer? ins 2 - drawer c, ins 2, drawer a, inst 1 drawer a, ins 1 drawer b.Are there multiple at same time? yes, 15 vials in total.Time to positive (in hours) - pending.Protocol length (days) 5 days.Do you have a ups unit on your instrument(s)? no.Environmental factors: temperature variations? power outages? construction? locations of vents/windows? vibrations (hvac, construction)? customer has indicated recent gap failures.A fse was on the site today and fixes the reading gap failure.Soon after the fse left, the customer reported receiving 8 fps.Has your instrument been serviced (repair or pms) prior to the events of fp? (confirm service history) yes, just today.Has your instrument been serviced following the events and did it stop the fp? (confirm service history) no, it was only services before the several fps (b)(6): 2022-05-05 13:41:55 (gmt).Applications has placed plots in q:\bactec fx accounts\ (b)(6).(b)(4).(b)(6): 2022-05-05 13:39:00 (gmt).Date: 5/5/2022.S/n: (b)(6).Customer inquiry/problem: case requested by rcc.Customer reporting false positives on multiple instruments within 1 hour of service performed for case: (b)(4).Steps taken with customer:  synapsys engineer working on remote connection to collect logs.Next steps (if necessary): sme review of logs and follow up.Rationale why no complaint is required (if interaction only): resolution achieved (y/n)? yes/no dispatch needed.Parts recommended: n/a.Rma required? n/a.Software version: not provided.Vials affected (for blood culture only)? yes, subculturing.Recommended.Follow up requested: yes.Only complete this box if dispatch is needed.Dispatch priority determination: q1.Able to process samples? q2.Able to maintain workflow? priority status: (status is based on the customer, not the instrument.) remote assist avail? no.Reviewed smx case history: yes.(b)(6): 2022-05-05 13:20:39 (gmt).False positives shortly after rack replacement on (b)(6).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD BACTEC¿ FX, INSTRUMENT BOTTOM, PACKAGED
Common Device Name
SYSTEM, BLOOD CULTURING
Manufacturer (Section D)
BECTON, DICKINSON & CO. (SPARKS)
7 loveton circle
sparks MD 21152
Manufacturer (Section G)
BECTON, DICKINSON & CO. (SPARKS)
7 loveton circle
sparks MD 21152
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key14575948
Report Number1119779-2022-00797
Device Sequence Number17412595
Product Code MDB
UDI-Device Identifier00382904413866
UDI-Public00382904413866
Combination Product (Y/N)N
Initial Reporter StateMN
Initial Reporter CountryUS
PMA/510(K) Number
K915796
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 09/12/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Model Number441386
Device Catalogue Number441386
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/05/2022
Supplement Date Received by Manufacturer09/12/2022
Initial Report FDA Received Date06/02/2022
Supplement Report FDA Received Date09/19/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured03/09/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-