SMITH & NEPHEW ORTHOPAEDICS AG TRIAL FEMORAL HEAD 28 S/+0; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/CERAMIC/POLYMER, CEMENTED OR NON-POROUS Back to Search Results
Model Number 75100844
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/13/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Internal complaint reference: case (b)(4).
 
Event or Problem Description
It was reported that the trial femoral head 28 s/+0 broke.As this was noticed after surgery, the patient was no longer involved.
 
Additional Manufacturer Narrative
H3, h6: it was reported that the trial femoral head 28 s/+0 broke.The device was not returned for investigation and the batch number is unknown.A product evaluation could therefore not be performed.However, a complaint history review was performed.The occurrence of the reported failure mode is within its expected risk level as per risk management.A review of the risk management documentation verifies the failure mode and severity of the reported issue.Due to insufficient information, it is not possible to perform a review of past corrective actions.A relationship between the reported event and the device cannot be confirmed.Based on the available information it is not possible to investigate whether the reported device met manufacturing specifications upon release for distribution.The root cause for the reported issue remains undetermined.Due to insufficient information, it is not possible to speculate about factors which could have contributed to the reported event.No further actions have been initiated.If the reported device or additional information become available, this investigation will be reopened.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIAL FEMORAL HEAD 28 S/+0
Common Device Name
PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/CERAMIC/POLYMER, CEMENTED OR NON-POROUS
Manufacturer (Section D)
SMITH & NEPHEW ORTHOPAEDICS AG
schachenallee 29
aarau CH-50 00
SZ  CH-5000
Manufacturer (Section G)
SMITH & NEPHEW ORTHOPAEDICS AG
schachenallee 29
aarau CH-50 00
SZ   CH-5000
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key14580891
Report Number9613369-2022-00268
Device Sequence Number2058103
Product Code LZO
UDI-Device Identifier07611996121773
UDI-Public07611996121773
Combination Product (Y/N)N
Initial Reporter StateKY
Initial Reporter CountryUS
PMA/510(K) Number
K132435
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/27/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number75100844
Device Catalogue Number75100844
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/13/2022
Supplement Date Received by Manufacturer06/24/2022
Initial Report FDA Received Date06/02/2022
Supplement Report FDA Received Date06/27/2022
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-