MAUDE Adverse Event Report: STRYKER NEUROVASCULAR CORK TRANSFORM SUPER COMPLIANT 4MM X 7MM - US; CATHETER, INTRAVASCULAR OCCLUDING, TEMPORARY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER NEUROVASCULAR CORK TRANSFORM SUPER COMPLIANT 4MM X 7MM - US; CATHETER, INTRAVASCULAR OCCLUDING, TEMPORARY Back to Search Results
Model Number M003SSC04070
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Hemorrhage/Blood Loss/Bleeding (1888); Perforation of Vessels (2135)
Date of Event 05/10/2022
Type of Reportable Event Death
Additional Manufacturer Narrative
This is 1 of 4 reports.The device is not available to the manufacturer.
 
Event or Problem Description
It was reported that during the anterior cerebral aneurysm (aca) coil embolization procedure while placing the embolization coil inside the aneurysm the physician noticed a thrombus forming close to the neck of the aneurysm.The physician stopped the coiling and removed the microcatheter from the patient's anatomy.Administered pharmacological agents to the patient to address the thrombus, after a few minutes, the physician did a contrast run and still saw slow flow into the aca and contralateral a2.The physician planned to stent the artery so another microcatheter and guide wire was placed into the ipsilateral a2.At this point, there was no contrast seen flowing into the other a2, then the physician decided to perform aspiration.Guidewire and microcatheter were placed into the vessel had the thrombus/no blood flow.The physician took the guide wire distal to the location of the thrombus and used the aspiration catheter to take the thrombus out of the patient's anatomy.Prior to the aspiration the physician performed a contrast run through the artery, extravasation and artery perforation could be seen near the contralateral a2.The physician administers protamine to the patient as a additional medication and used an subject occlusion balloon catheter to place up to the site of artery perforation.Then the subject occlusion balloon was inflated in the a1 segment without any difficulty.The subject occlusion balloon was deflated and navigated proximally into the internal carotid artery (ica).The subject occlusion balloon was again inflated and visible upon inflation and the contrast run showed that there had been a rupture of the internal carotid artery.The subject occlusion balloon and guidewire were removed from the patient's anatomy.As a medical intervention, the physician placed an external ventricular drain (evd) and coiled off the ica.Post procedure the patient was passed away and the physician does not allege any malfunction against the device used in the procedure that could have caused the patient death.
 
Event or Problem Description
It was reported that during the anterior cerebral aneurysm (aca) coil embolization procedure while placing the embolization coil inside the aneurysm the physician noticed a thrombus forming close to the neck of the aneurysm.The physician stopped the coiling and removed the microcatheter from the patient's anatomy.Administered pharmacological agents to the patient to address the thrombus, after a few minutes, the physician did a contrast run and still saw slow flow into the aca and contralateral a2.The physician planned to stent the artery so another microcatheter and guide wire was placed into the ipsilateral a2.At this point, there was no contrast seen flowing into the other a2, then the physician decided to perform aspiration.Guidewire and microcatheter were placed into the vessel had the thrombus/no blood flow.The physician took the guide wire distal to the location of the thrombus and used the aspiration catheter to take the thrombus out of the patient's anatomy.Prior to the aspiration the physician performed a contrast run through the artery, extravasation and artery perforation could be seen near the contralateral a2.The physician administers protamine to the patient as a additional medication and used an subject occlusion balloon catheter to place up to the site of artery perforation.Then the subject occlusion balloon was inflated in the a1 segment without any difficulty.The subject occlusion balloon was deflated and navigated proximally into the internal carotid artery (ica).The subject occlusion balloon was again inflated and visible upon inflation and the contrast run showed that there had been a rupture of the internal carotid artery.The subject occlusion balloon and guidewire were removed from the patient's anatomy.As a medical intervention, the physician placed an external ventricular drain (evd) and coiled off the ica.Post procedure the patient was passed away and the physician does not allege any malfunction against the device used in the procedure that could have caused the patient death.
 
Additional Manufacturer Narrative
F10/h6 clinical signs code grid- updated.Although the device history record (dhr) could not be reviewed because the lot number remains unknown, there are controls in the manufacturing process to ensure the product met specifications upon release.The subject device is not available; therefore, functional testing as well as visual testing cannot be performed.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.The reported complaint could not be confirmed, and it could not be definitively determined if the device failed to meet specifications because the product was not returned.It was reported that a balloon had been prepped according to the dfu.Once seeing the extravasation and artery perforation, protamine was administered to the patient and opted to bring the balloon up to the site of artery perforation.The balloon was inflated in the a1 and the balloon was visible.Subsequently, he deflated the balloon and navigated it proximally into the internal carotid artery.The balloon was again inflated and visible upon inflation.The next contrast run showed that there had been a rupture of the internal carotid artery.The physician removed the balloon and wire.After an external ventricular drain had been placed, he coiled off the internal carotid artery.Post procedure, the patient passed away.The physician assumed that the original perforation occurred from the wire.There was no alleged deficiency by the physician with any of the products used in this case.Based upon medical review, the harm observed in this complaint is anticipated in nature as per the device risk assessment.As a product related root cause does not apply and the issue is due to a known physiological effect of the procedure and/or patient condition noted within the dfu, product labeling and/or risk documentation files, an assignable cause of anticipated procedural complication will be assigned to this complaint of patient vessel perforation, patient hemorrhage, blood loss with sequalae and patient death.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRANSFORM SUPER COMPLIANT 4MM X 7MM - US
Common Device Name
CATHETER, INTRAVASCULAR OCCLUDING, TEMPORARY
Manufacturer (Section D)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI  NA
Manufacturer (Section G)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI   NA
Manufacturer Contact
tara lopez
47900 bayside parkway
fremont, CA 94538
5104132500
MDR Report Key14586128
Report Number3008881809-2022-00266
Device Sequence Number11267857
Product Code MJN
UDI-Device Identifier07613327004694
UDI-Public07613327004694
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K122576
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Risk Manager
Type of Report Initial,Followup
Report Date (Section B) 09/02/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberM003SSC04070
Device Catalogue NumberM003SSC04070
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 05/10/2022
Supplement Date Received by Manufacturer08/11/2022
Initial Report FDA Received Date06/03/2022
Supplement Report FDA Received Date09/02/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
3MAX REPERFUSION CATHETER (PENUMBRA).; EXCELSIOR SL-10 MICROCATHETER (STRYKER).; PC400 EMBOLIZATION COIL (PENUMBRA).; SYNCHRO SELECT STANDARD GUIDEWIRE (STRYKER).; TARGET COIL (STRYKER).
Outcome Attributed to Adverse Event Death; Required Intervention; Other;
Patient SexUnknown
-
-