Model Number M0036128300
Medical Device Problem Code Premature Separation (4045)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/11/2022
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during the procedure, physician felt resistance while advancing the subject coil within the microcatheter.The delivery wire of the subject coil seemed to be kinked, so it was retrieved and the subject coil was found detached prematurely inside the microcatheter.The subject coil was removed along with the microcatheter.The microcatheter was reinserted and the procedure was completely successfully.No clinical consequences were reported to the patient due to this event.
 
Additional Manufacturer Narrative
H4 manufacturing date - added d4 expiration date - added due to the automated mes system there are controls in the manufacturing process to ensure the product met specifications upon release.The subject device is not available; therefore, functional testing as well as visual testing cannot be performed.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.Additional information provided by the customer was when the subject coil was inserted into a catheter, there was significant resistance in the middle of the microcatheter.The resistance was so great that the delivery wire seemed to be kinked/bent, so it was retrieved and found that the coil had been prematurely detached.It was reported that the device was prepared as per the dfu, that there was no damage noted to the packaging prior to opening and the device was confirmed to be in good condition during preparation/prior to use on the patient.However, it was reported that continuous flush was not set up and maintained during the procedure.As per the dfu in order to achieve optimal performance of the detachable coil system it is critical that a continuous infusion of appropriate flush solution be maintained, as this was not carried out, its likely this caused the reported friction and premature detachment.So therefore, a probable cause of user error will be assigned to the as reported "coil in catheter friction", "coil delivery wire kinked/bent" and "main coil prematurely detached/separated during use", since there was a deviation from the supplied dfu that resulted in a different medical product response than intended by the manufacturer or expected by the user.
 
Event or Problem Description
It was reported that during the procedure, physician felt resistance while advancing the subject coil within the microcatheter.The delivery wire of the subject coil seemed to be kinked, so it was retrieved and the subject coil was found detached prematurely inside the microcatheter.The subject coil was removed along with the microcatheter.The microcatheter was reinserted and the procedure was completely successfully.No clinical consequences were reported to the patient due to this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TARGET XL 360 SOFT 8MM X 30CM
Common Device Name
DEVICE, NEUROVASCULAR EMBOLIZATION
Manufacturer (Section D)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI  NA
Manufacturer (Section G)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI   NA
Manufacturer Contact
tara lopez
47900 bayside parkway
fremont, CA 94538
5104132500
MDR Report Key14600210
Report Number3008881809-2022-00271
Device Sequence Number14989136
Product Code HCG
UDI-Device Identifier07613327004649
UDI-Public07613327004649
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K153658
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/12/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/25/2025
Device Model NumberM0036128300
Device Catalogue NumberM0036128300
Device Lot Number23424837
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 05/11/2022
Supplement Date Received by Manufacturer07/18/2022
Initial Report FDA Received Date06/06/2022
Supplement Report FDA Received Date08/12/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured01/27/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
CARRY LEON (UNKNOWN); UNION T&M (UNKNOWN)
Patient SexUnknown
-
-